8.7/15KV XLPE Insulation PVC Sheath Medium Voltage Cable SWA Armour
Applications
This 8.7/15kV XLPE Insulation PVC Sheath SWA (Steel Wire Armoured) Cable is commonly used for:
Underground Power Distribution – Reliable medium-voltage transmission in urban and industrial networks.
Direct Burial & Duct Installation – Protected by steel armour against mechanical damage and rodent attacks.
Industrial & Utility Applications – Suitable for power plants, substations, and heavy machinery connections.
Wet & Corrosive Environments – PVC sheath provides moisture and chemical resistance.
Outdoor & Exposed Installations – UV-resistant and durable for above-ground use when needed.
Its XLPE insulation ensures high thermal stability (up to 90°C), while the steel wire armour (SWA) enhances strength and safety. Ideal for fixed installations requiring robust protection.
Construction
Conductor:Class 2 stranded copper conductor
Conductor Screen :Semi-conductive XLPE (Cross-Linked Polyethylene)
Insulation :XLPE (Cross-Linked Polyethylene) Insulation
Screen :Semi-conductive XLPE (Cross-Linked Polyethylene)
Metallic Screen :Individual or collective overall copper tape screen
Filler :PET (Polyethylene Terephthalate) fibres Separator :Binding tape
Bedding :PVC (Polyvinyl Chloride)
Armour :Single core: AWA (Aluminium Wire Armoured)
Multi-core: SWA (Steel Wire Armoured)
Sheath :PVC (Polyvinyl Chloride)
Specification
Reference Standards:
|
IEC60502-2, IEC 60228, IEC60332 -1/2/3, BS6622, BS7835, VDE0276, AS/NZS 1429.1, GB/T 12706, etc.
|
Rated Voltage:
|
6/10kV, 6.35/11kV (12kV), 8.7/15kV, 12/20kV, 18/30kV,19/33kV
|
Core Number:
|
Single Core or Three Core (1C or 3C)
|
Available Dimensions:
|
25mm2, 35mm2, 50mm2, 70mm2, 95mm2, 120mm2, 150mm2, 185mm2, 240mm2, 300mm2, 400mm2, 500mm2, 630mm2.
|
Codes Available:
|
N2XSY, N2XSEY, NA2XSY, NA2XSEY, N2XSRY, NA2XSRY, N2XSEBY, N2XSEYBY, NA2XSEBY, N2XSERY, NA2XSERY, N2XSEYRGbY, NA2XSEYRGbY,
N2XS(F)2Y, NA 2XS(F)2Y, N2XS(FL)2Y, N2XSH, N2XSYRY
|
YJV, YJLV, YJSV, YJLSV, YJV72, YJLV72, YJSV72, YJLSV72, YJV22, YJLV22, YJSV22, YJLSV22, YJV32, YJLV32, YJSV32, YJLSV32
|
Application:
|
For power networks, underground, outdoors and in cable ducting. It is recommended that the installation instructions indicated by
the Local Electric Code, or any equivalent, be followed, so that the safeguarding of persons and the integrity of the product will
not be affected during installation.
|
Construction:
|
|
Conductor:
|
Stranded round compacted copper or aluminum conductor (Cu / Al ), copper wire annealed.
|
Conductor Screen:
|
Semi-conducting material
|
Insulation:
|
XLPE (Cross-Linked Polyethylene)
|
Insulation Screen:
|
Semi-conducting material
|
Metallic Screen:
|
Copper tape screen or copper wire screen (CTS / CWS )
|
Filler:
|
PP rope
|
Separator:
|
Binding tape
|
Bedding:
|
PVC (Polyvinyl Chloride)
|
Armouring:
|
Single Core: Aluminium Wire Armoured (AWA) Multi-core: Steel Wire Armoured (SWA) or Steel Tape Armoured (STA)
|
Sheath:
|
PVC (Polyvinyl Chloride), flame retardant PVC, PE, LSOH, HFFR
|
Colour:
|
Red or Black
|
Temperature Rating:
|
0°C to 90°C
|
Minimum Bending Radius:
|
Single Core: 15 x overall diameter Three Core: 12 x overall diameter (Single Core 12 x overall diameter and 3 core 10 x overall
diameter where bands are positioned adjacent to joint or terminations provided that the bending is carefully controlled by the use
of a former
|