| Model | 12VDC Series |
| Power | 1.0KW |
|
Line Mode Specifications: |
|
|
Input Voltage Waveform |
Sinusoidal (utility or generator) |
|
Nominal Input Voltage |
110-120Vac |
|
Low Line Disconnect |
80Vac±4% / 90Vac±4% |
|
Low Line Re-connect |
90Vac±4% / 100Vac±4% |
|
High Line Disconnect |
140Vac±4% |
|
High Line Re-connect |
135Vac±4% |
|
Max AC Input Voltage |
0~150Vrms |
|
Nominal Input Frequency |
50Hz / 60Hz (Auto detection) |
|
Low Line Frequency Re-connect |
58±0.3Hz for 60Hz; 48±0.3Hz for 50Hz; |
|
Low Line Frequency Disconnect |
57±0.3Hz for 60Hz; 47±0.3Hz for 50Hz; |
|
High Line Frequency Re-connect |
64±0.3Hz for 60Hz; 54±0.3Hz for 50Hz; |
|
High Line Frequency Disconnect |
65±0.3Hz for 60Hz; 55±0.3Hz for 50Hz; |
| Output Voltage Waveform | As same as Input Waveform |
|
Over-Load Protection (SMPS load) |
Circuit breaker |
|
Output Short Circuit Protection |
Circuit breaker |
|
Efficiency (Line Mode) |
>95% |
|
Transfer Switch Rating |
30Amp for UL & TUV 40Amp for UL |
|
Transfer Time (Ac to Dc) |
10ms Max |
|
Transfer Time (Dc to Ac) |
10ms Max |
|
Pass through without Battery |
YES |
|
Max Bypass Overload Current |
40A |
| Invert Mode Specifications: | |
| MODEL POWER TYPE | Any Power Combi Series |
| APC 1012 ~ 6048 | |
| Output Voltage Waveform | Pure Sine Wave |
| Rated Output Power (VA/W) | 1KW |
| Power Factor | 0~1.0 |
| Nominal Output Voltage (V) | 110-120Vac |
| Nominal Output Frequency (Hz) (Default) | 60Hz |
| Auto Tracking Main Frequency (First Connection) | |
| Output Voltage Regulation | ±10% RMS |
| Nominal Efficiency | >88% |
|
Over-Load Protection (SMPS Load) |
(110%(125%( Load>150%) ±10%: Fault (shutdown output) after 20s; |
| Surge Rating | 3.0 |
| Capable of Starting Electric Motor | 1HP |
| Output Short Circuit Protection | Current Limit Function (Fault after 1sec) |
| Bypass Breaker Size | 10A |
| Nominal DC Input Voltage | 12.0Vdc |
| Min DC Start Voltage | 10.0 |
| Low Battery Alarm | 10.5 |
| Low DC Input Shut-Down | 10.0 |
| Low DC Input Auto-Restart | 13.0Vdc |
| High DC Input Alarm & Fault | 16.0Vdc |
| High DC Input Recovery | 15.5Vdc |
|
Power Saver Function Remark: Detail P/S setting refers Appendix 1. |
Load ≦25W (Enabled On “P/S AUTO” Setting of Remote Control) |