Industrial Servo Inverter VFD: 0-400Hz Adjustable Speed, Full Protection For Pumps & Fans
  1. Core Features
  
    - Wide Speed Range (0-400Hz)
      
        - Enables precise speed control for low-speed (e.g., gentle fan rotation) and high-speed (e.g., centrifugal pump acceleration) applications.
 
        - Supports soft start/stop to reduce mechanical stress and energy consumption.
 
      
     
    - Full Motor Protection Suite
      
        - Overload Protection : Automatically trips if current exceeds rated capacity (e.g., 150% overload for 1 minute).
 
        - Overvoltage/Undervoltage Protection : Safeguards against voltage surges (e.g., lightning strikes) or drops (e.g., grid instability).
 
        - Overheating Protection : Monitors IGBT temperature and shuts down if thermal limits are exceeded.
 
        - Phase Loss Protection : Detects missing phases (e.g., L1, L2, L3) and prevents motor burnout.
 
        - Ground Fault Protection : Isolates the system during insulation failures to prevent electric shocks.
 
      
     
    - Optimized for Pumps & Fans
      
        - PID Control : Adjusts motor speed in real-time to maintain constant pressure (pumps) or airflow (fans), reducing energy waste by up to 30%.
 
        - Sleep/Wake Function : Automatically powers down pumps/fans during idle periods (e.g., nighttime) and restarts when demand resumes.
 
        - Dry Run Protection : For pumps, detects low liquid levels and stops the motor to prevent damage.
 
      
     
  
  2. Technical Specifications
  
    
      | Parameter | 
      Details | 
    
    
      | Input Voltage | 
      Single-phase 220V or three-phase 380V ±15% (50/60Hz) | 
    
    
      | Output Frequency | 
      0-400Hz (adjustable via keypad/remote control) | 
    
    
      | Control Modes | 
      V/F, Sensorless Vector Control (SVC), Torque Control | 
    
    
      | Enclosure Rating | 
      IP20 (indoor) or IP55 (outdoor/dusty environments) | 
    
    
      | Communication | 
      RS485 (Modbus RTU), optional Profibus-DP/EtherCAT | 
    
    
      | Display | 
      LED/LCD screen showing frequency, current, fault codes, and operating status | 
    
  
  3. Key Applications
  
    - Centrifugal Pumps
      
        - Challenge : Throttling valves waste energy when reducing flow.
 
        - Solution : VFD adjusts pump speed to match demand, cutting power use by 40% (e.g., HVAC cooling towers).
 
      
     
    - Axial Flow Fans
      
        - Challenge : Fixed-speed fans cause noisy operation and excessive airflow.
 
        - Solution : VFD ramps down fan speed during low-demand periods (e.g., nighttime ventilation), reducing noise by 10dB.
 
      
     
    - Water Treatment Systems
      
        - Challenge : Manual control leads to inconsistent chemical dosing.
 
        - Solution : VFD integrates with flow meters and PID loops to maintain precise dosing rates (e.g., chlorine injection pumps).
 
      
     
  
  4. FAQs
  
    Q: Can this VFD handle single-phase motors?
    A: No, it requires three-phase motors. For single-phase applications, use a phase converter or a dedicated single-phase VFD.
   
  
    Q: How often should I perform maintenance?
    A: Check cooling fans and heat sinks every 6 months. Replace capacitors every 5-7 years.
   
  
    Q: Is IP55 necessary for indoor use?
    A: Not required, but IP55 models resist dust and accidental water splashes, extending lifespan in workshops.