Specifications
Brand Name :
drager
Model Number :
6850645
Certification :
CE,ISO
Place of Origin :
Germany
MOQ :
1pcs
Price :
as discussed
Payment Terms :
T/T, Western Union,
Supply Ability :
300pcs / week
Delivery Time :
5-7 work days
Packaging Details :
1pcs / bag
COLOR :
silver
brand :
drager
material :
Mixture
warranty :
12 months
name :
o2 sensor medical
approval :
CE,ISO
Description

Original and new drager medical Oxygen sensor 6850645 for Ventilator 6850645 O2 sensor O2 cell

Sensor Specifications & Compatibility
Catalog Number
Output Signal in Air 24A - 32A (Dual Cathode) no temperature compensation
Response Time T 90% < 12 seconds
Nominal Sensor Lifetime 500 000 % volume Oxygen hours
Electrical Interface Gold plated slip rings
Compatibility: Draeger 6850645 (Dr¤ger)
Babylog, Fabian, Cicero, PM8030
Evita, Oxydig, Anemone, Oxycom
Incubator 8000
M08 ST13
MAX11
Invivo Magnitude
10-103-07
PT14A
Teledyne R13 C-61139
Hudson 5557 (V14)
VTI 101372, 100352
* Note: Order E61720 with reusable cap and "o" rings
Medical Oxygen Sensors (Fuel Cells) general specifications:
Measurement Range: 0-100 % oxygen
Accuracy and Repeatability: < 1 % vol. O2when calibrated at 100 % O2
Zero Ofset: < 0.5 % vol. O2in 100% N2, applied 5 minutes
Linearity Error: < 3 % relative
Cross Interference: < 0.5 % vol. O2response to:
10 % CO2balance N2
80% N2O balance N2
7.5% Halothane balance N2
7.5 % Isofurane balance N2
7.5 % Enfurane balance N2
9% Sevofurane balance N2
20% Desfurane balance N2
Infuence of Humidity: - 0.03 % rel. per % RH at 25C
Infuence of Pressure: proportional to change in oxygen partial
pressure
Infuence of Mechanical Shock: < 1% relative after a fall from 1m
Operating Temperature: 0 to 50C
Temperature Compensation: built-in NTC compensation (see below)
Efect of Temperature between +5 C and +25 C: 3 % relative error
Compensation (steady state): between 0 C and +50 C: 8 % relative error
Operating Humidity: 0-99 % RH non-condensing
Long Term Output Drift: < 1 % vol oxygen per month
typically < - 15 % relative over lifetime
Storage Temperature: -20 to +50 C
Recommended Storage: +5 to +15 C
Recommended Load: 10 kOhms
Warm-Up Time: < 30 minutes, after replacement of sensor
Weight: approximately 28 grams
approximately 43 grams E61912 series
Designed and manufactured according to EN ISO 9001 : 2000 and EN13485 : 2003
specifications are applicable at standard conditions: 1013 hPa, 25C dry ambient air
Oxygen sensor for Draeger OEM 6850645
Envitec 6850645

Ventilator Medical O2 Sensor , Quick React Original New O2 Sensor Medical

Send your message to this supplier
Send Now

Ventilator Medical O2 Sensor , Quick React Original New O2 Sensor Medical

Ask Latest Price
Brand Name :
drager
Model Number :
6850645
Certification :
CE,ISO
Place of Origin :
Germany
MOQ :
1pcs
Price :
as discussed
Contact Supplier
Ventilator Medical O2 Sensor , Quick React Original New O2 Sensor Medical
Ventilator Medical O2 Sensor , Quick React Original New O2 Sensor Medical

Shenzhen Pray-med Technology Co.,Ltd

Verified Supplier
8 Years
guangdong, shenzhen
Since 2010
Business Type :
Manufacturer, Distributor/Wholesaler, Agent, Exporter, Seller
Total Annual :
1000000-5000000
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement