The result is clean, purified air that is safely discharged into the atmosphere. For operator safety, the unit is equipped with reliable protection devices and a convenient, automated oil drainage system.


Feature | Electrostatic oil mist Collector | Mechanical oil mist Collector | Centrifugal oil mist Collector |
Working Principle | Electrostatic Precipitation | Physical Filtration | High-Speed Centrifugal Separation |
Recommended Coolant | Oil / Cutting Oil | Coolant / Cutting Fluid | Both Coolant &Cutting Oil (Universal) |
Filtration Efficiency | 99% | 99% | 99% |
onsumables | No consumables needed (Only periodic cleaning of the electric field) | Regular filter replacement required (Approx. every 6-12 months) | Regular filter replacement required (Approx. every 6-12 months) |
Suction Power | Stable,Very Powerful | Stable | Very Powerful |
Noise Level | Low | Low | Relatively High (approx. 65 dB) |
Ideal Application | using Oil / Cutting Oil and wanting to avoid consumables | Most CNC machines using coolant | Large machine tools, Machining centers, scenarios demanding high suction |
Key Advantage | Superior purification, low long-term cost | Cost-effective, proven technology | Cost-effective,Powerful, high capacity |
Selection Keyword | No Consumables, High Purification, Oil | Cost-Effective, Coolant,quiet, and stable | Cost-effective,High Power, Strong Suction, Large Machines |



Model | Air volume (m3/h) | power (w) | Inlet diameter (mm) | rated voltage (v) | Applicable Volume | Equipment size (mm) |
DFY-20 | 1050 | 180 | 150 | 220/380 | within2m³ | 695*515*480mm |
DFY-40 | 1225 | 240 | 150 | 220/380 | within 3-4m³ | 760*580*625mm |
DFY-50 | 1600 | 420 | 150 | 220/380 | within 4-5m³ | 1140*515*480mm |
DFY-60 | 2250 | 480 | 160 | 220/380 | within 5 m³ | 1140*580*625mm |
DFY-80 | 4050 | 700 | 200 | 220/380 | within 6 m³ | 1630*580*625mm |
DFY-110 | 4500 | 1500 | 200 | 220/380 | within 10 m³ | 1965*580*625mm |