Safe and effective uv-c disinfection lamp 40w 60w supermarket air sterilization
Advantages:
Hide the UV-C light source, no harm to people and objects
Active convection of the fan improves the sterilization efficiency and reduces the dead angle
40W and 60W power can provide enough 253.7-nanometer sterilization ultraviolet radiation.
Suitable for air disinfection and purification in daily indoor scenes, long-term work available.
Tests have verified that the product can effectively kill the H1N1 virus, Escherichia coli, Staphylococcus Albicans, and other harmful microorganisms in the air.
Application:
This product is suitable for indoor air disinfection in offices, restaurants, cafes, bars, shopping malls, schools, homes, hospitals, industry, museums, retail and other places.
Main Performance and Parameters:
| Parameters Items | GY1331UV40 | GY1359UV60 |
| Rated Power | 40 W | 60W |
| Input Voltage | AC220-240V 50/60 Hz | |
| Power Factor | ≥0.9 | |
| UV-C Light Type | Philips TUV PL-L UV-C Light | |
| Peak Wavelength | 253.7nm | |
| Light Source Life | 10000H | |
| Disinfection Type | Common bacteria, viruses, and other microorganisms | |
| Recommended Using Area Dimension | 10-15m² | 15-20m² |
| Recommended Filter Replacement Frequency | 3-6 months | |
| Working Duration Limit | Available for long-term operation | |
| IP Rating | IP20 | |
| Electric Safety Class | CLASS I | |
| Surface Treatment | Anti-corrosive powder coating | |
| Dimension | 318*133*121mm | 638*133*121mm |
| Net Weight | 2.1Kg | 3.8Kg |
| Executive National Standard | GB28235;GB19258;Q/141000 GY008—2021 | |
Product Features
• The product has no working time limit and can work for a long time.
• UV-C "closed" cavity disinfection, safe and reliable.
• Active convection design, high disinfection efficiency.
• Branded light source to ensure a stable output of ultraviolet radiation.
• The power of the product is 40W and 60W, providing sufficient ultraviolet radiation for disinfection.
• No ozone is generated when the product is working.
• Knob-type light source replacement method, fast and convenient.
• The filter is fixed by a buckle, which is clean and easy to replace.
• Vertical wall mounting, fixed distribution, simple construction, and operation.
Troubleshooting:
| SN | Fault Description | Cause of Fault | Troubleshooting Method |
| 1 | The power is on, the indicator light is off, and the fan is working normally | UV-C light is damaged | Replace with a new UV-C light |
| 2 | The power is on, the indicator light is off, and the fan does not work | The socket has no electricity, or the product switch is faulty | Check whether the socket is electrified. If the socket has electricity, check whether the input circuit such as the product switch is normal |
| 3 | The fan noise has increased significantly | Too much dust on the filter | Replace with a new filter |