Description
1 Application
Space-heaters for Non-hazardous locations are designed for
- Freeze protection
- Anti-condensation
- Temperature maintenance
2 Features and Advantages
- Self-limiting heating elements
- Small dimensions
- No moving parts, no maintenance required, therefore long lifetime
- Can be used for 110 / 240 VAC/DC
3 Remarks
- All Cameo Space-heaters are designed around self-limiting heating elements. These semiconductor elements are saving power consumption.
- Our Cameo Space-heaters are designed to heat the air inside an enclosure and indirectly the installed equipment. If properly selected for freeze protection, no thermostat will be needed.
- When required in other applications, e.g. analyzers, it is normal practice to use our Space-Heaters in combination with our Fix-Therm96 thermostats (range from 10 °C up to 135 °C).
- Do not cover the fins to guarantee free convection.
4 Range
| GLP-1A - T3 | ca. 115°C Surface temperature | 100-10 Watt |
| GLP-2A - T4 | ca. 105°C Surface temperature | 100-10 Watt |
| GLP-3A - T4 | ca. 90°C Surface temperature | 100-10 Watt |
| GLP-4A - T4 | ca. 70°C Surface temperature | 100-10 Watt |
GLP-0AHP - T3 (High power model) | ca. 130°C Surface temperature | 200-20 Watt |
* these temperatures are measured at 20°C ambient temperature.

5 Technical data
| Power consumption | 100-10 Watt or 200-20 Watt |
| Electrical cable | 3 x 1 sqmm |
| Material cable | non-braided silicone cable |
| Standard length | ca. 1 mtr., other lengths optional |
| Other lengths | to be specified |
| Weight | Aluminium heater ca. 350 g., 316 Stainless Steel 480 g. |
| Overall dimensions | 78 x 30 x 34 mm (LxWxH) |
| Material | black anodized aluminium (A) or 316 stainless steel (S) |
| Voltage AC/DC | 110/240 |