Specifications
Delivery Time :
in stock
Model Number :
HI83300
Price :
USD$1598
Packaging Details :
Original packaging
Supply Ability :
10PC
Payment Terms :
L/C, D/A, D/P, T/T, Western Union
Place of Origin :
China
Brand Name :
HANNA
MOQ :
1
Description
GENERAL
MEASUREMENT CHANNELS 5 X OPTICAL CHANNELS; 1 X SMART ELECTRODE CHANNEL (pH MEASUREMENT)
Absorbance Range 0.000Abs-4.000Abs
Absorbance Resolution 0.001 Abs
Absorbance Accuracy ±0.003 Abs (at 1.000 Abs)
Absorbance Light Source Light-emitting diode
Absorbance Bandpass Filter Bandwidth 8nm
Absorbance Bandpass Filter Wavelength Accuracy ±1.0nm
Light Detector Silicon photocell
Cuvette Type round, 24.6 mm diameter
Number of Methods 128 max
pH Range -2.00 to 16.00 pH (±1000mV)*
pH Resolution 0.01 pH (0.01 mV)*
Temperature Compensation ATC (-5.0 to 100.0°C;*)
Additional Specifications:
Logging 1000 readings (mixed photometer and electrode)
Display 128 x 64 pixel B/W LCD with backlight
USB-A (host) functions mass-storage host
USB-B ( Device) Functions power input, mass-storage device
Battery Life >500 Photometer measurements, or 50 hours of continuous pH measurement
Power supply 5 VDC USB 2.0 power adapter/ type micro-B connector 3.7 VDC Li-polymer rechargeable battery, non-serviceable
Environment 0 to 50°C; 0 to 95% RH, non-condensing
Dimensions 206 x 177 x 97mm
Weight 1.0kg
Ordering Information HI-83300 is supplied with sample cuvettes and caps (x4), cloth for wiping cuvettes, USB to micro USB cable connector, power adapter and instruction manual.
*Limits will be reduced to actual sensor limits

ABSORBANCE

Absorbance Range 0.000 to 4.000 Abs
Absorbance Resolution 0.001 Abs
Absorbance Accuracy +/-0.003Abs @ 1.000 Abs

ALKALINITY - Reagents - HI-93755-01 (100 tests); HI-93755-03 (300 tests)

Alkalinity Range Freshwater: 0 to 500 mg/L (as CaCO3) Marine: 0 to 300 mg/L (as CaCO3)
Alkalinity Resolution 1 mg/L
Alkalinity Accuracy ±5 mg/L ±5% of reading
Alkalinity Method Colorimetric method

ALUMINIUM - Reagents - HI-93712-01 (100 tests); HI-93712-03 (300 tests)

Aluminium Range 0.00 to 1.00 mg/L (as Al3+)
Aluminium Resolution 0.01 mg/L
Aluminium Accuracy ±0.04 mg/L ±4% of reading
Aluminium Method Adaptation of the aluminon method

AMMONIA - Reagents: HR - HI-93733-01 (100 tests); HI-93733-03 (300 tests)
MR - HI-93715-01 (100 tests); HI-93715-03 (300 tests)
LR - HI-93700-01 (100 tests); HI-93700-03 (300 tests)

Ammonia Range Low Range: 0.00 to 3.00 mg/L (as NH3-N) Medium Range: 0.00 to 10.00 mg/L (as NH3-N) High Range: 0.0 to 100.0 mg/L (as NH3-N)
Ammonia Resolution 0.01 mg/L; 0.1 mg/L
Ammonia Accuracy Low Range: ±0.04 mg/L ±4% of reading Medium Range: ±0.05 mg/L ±5% of reading High range: ±0.5 mg/L ±5% of reading at 25 °C
Ammonia Method Adaptation of the ASTM Manual of Water and Environmental Technology, D1426-92, Nessler method

ANIONIC SURFACTANTS

Anionic Surfactants Range 0.00 to 3.50 mg/L (as SDBS)
Anionic Surfactants Resolution 0.01 mg/L
Anionic Surfactants Accuracy ±0.04 mg/L ±3% of reading
Anionic Surfactants Method Adaptation of the USEPA method 425.1 and Standard Methods for the Examination of Water and Wastewater, 20th edition, 5540C, Anionic Surfactants as MBAS.

BROMINE - Reagents: HI-93716-01 (100 tests); HI-93716-03 (300 tests)

Bromine Range 0.00 to 8.00 mg/L (as Br2)
Bromine Resolution 0.01 mg/L
Bromine Accuracy ±0.08 mg/L ±3% of reading
Bromine Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, DPD method.

CALCIUM - Reagents: HI-937521-01 (50 tests); HI-937521-03 (150 tests)

Calcium Range Freshwater: 0 to 400 mg/L (as Ca2+) Seawater: 200 to 600 mg/L (as Ca2+)
Calcium Resolution 1 mg/L
Calcium Accuracy Freshwater: ±10 mg/L ±5% of reading Seawater: ±6% of reading
Calcium Method Freshwater: Adaptation of the Oxalate method Seawater: Adaptation of the Zincon method

CHLORIDE - Reagents: HI-93753-01 (100 tests); HI-93753-03 (300 Tests)

Chloride Range 0.0 to 20.0 mg/L (as Cl⁻)
Chloride Resolution 0.1 mg/L
Chloride Accuracy ±0.5 mg/L ±6% of reading at 25 °C

CHLORINE DIOXIDE - Reagents: HI-93738-01 (100 tests); HI-93738-03 (300 tests)

Chlorine Dioxide Range 0.00 to 2.00 mg/L (as ClO2)
Chlorine Dioxide Resolution 0.01 mg/L
Chlorine Dioxide Accuracy ±0.10 mg/L ±5% of reading
Chlorine Dioxide Method Adaptation of the Chlorophenol Red method.

CHLORINE - Free Chlorine Reagents: HI-93701-01 (100 tests); HI-93701-03 (300 tests); HI-93701-F (liquid) (300 tests)
Chlorine UHR Reagents: HI-95771-01 (100 tests); HI-95771-03 (300 tests)
Chlorine, Free and Total HR: HI-93734-01 (100 tests); HI-93734-03 (300 tests)
Chlorine, Free ULR: HI-95762-01 (100 tests); HI-95762-03 (300 tests)
Chlorine Total: HI-93711-01 (100 tests); HI-93711-03 (300 tests); HI-93711-T (300 tests liquid)
Chlorine, Total ULR: HI-95761-01 (100 tests); HI-95761-03 (300 tests)

Free Chlorine Range 0.00 to 5.00 mg/L (as Cl2) Ultra Low Range: 0.000 to 0.500 mg/L (as Cl2)
Free Chlorine Resolution 0.01 mg/L Ultra Low Range: 0.001 mg/L
Free Chlorine Accuracy ±0.03 mg/L ±3% of reading Ultra Low Range: ±0.020 mg/L ±3% of reading
Total Chlorine Range 0.00 to 5.00 mg/L (as Cl2) Ultra Low Range: 0.000 to 0.500 mg/L (as Cl2) Ultra High Range: 0 to 500 mg/L (as Cl2)
Total Chlorine Resolution 0.01 mg/L; 0.001 mg/L; 1 mg/L
Total Chlorine Accuracy ±0.03 mg/L ±3% of reading Ultra Low Range: ±0.020 mg/L ±3% of reading Ultra High Range: ±3 mg/L ±3% of reading
Chlorine Method Adaptation of the EPA 330.5 DPD method Free Chlorine (ULR) & Total Chlorine (UHR): Adaptation of the Standard Methods for Examination of Water and Wastewater, 20th edition, 4500-Cl

CHROMIUM, HEXAVALENT - Reagents: HR - HI-93723-01 (100 tests); HI-93723-03 (300 tests)
LR - HI-93749-01 (100 tests); HI-93749-03 (300 tests)

Chromium, Hexavalent Range Low Range: 0 to 300 μg/L (as Cr6+) High Range: 0 to 1000 μg/L (as Cr6+)
Chromium, Hexavalent Resolution 1 μg/L
Chromium, Hexavalent Accuracy Low Range: ±1 μg/L ±4% of reading High Range: ±5 μg/L ±4% of reading
Chromium, Hexavalent Method Adaptation of the ASTM Manual of Water and Environmental Technology, D1687-92, Diphenylcarbohydrazide method.

COLOUR, WATER

Colour, Water Range 0 to 500 PCU (Platinum Cobalt Units)
Colour, Water Resolution 1 PCU
Colour, Water Accuracy ±10 PCU ±5% of reading
Colour, Water Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Colorimetric Platinum Cobalt method.

COPPER - Reagents: HR - HI-93702-01 (100 tests); HI-93702-03 (300 tests)
Total copper - HI-93702T - 01 (100 tests); HI-93702T-03 (300 tests)
LR - HI-95747-01 (100 tests); HI-95747-03 (300 tests)

Copper Range Low Range: 0.000 to 1.500 mg/L (as Cu2+) High range: 0.00 to 5.00 mg/L (as Cu2+)
Copper Resolution 0.001 mg/L; 0.01 mg/L
Copper Accuracy Low Range: ±0.01 mg/L ±5% of reading High Range ±0.02 mg/L ±4% of reading
Copper Method Adaptation of the EPA bicinchoninate method

CYANURIC ACID - Reagents: HI-93722-01 (100 tests); HI-93722-03 (300 tests)

Cyanuric Acid Range 0 to 80 mg/L (as CYA)
Cyanuric Acid Resolution 1 mg/L
Cyanuric Acid Accuracy ±1 mg/L ±15% of reading
Cyanuric Acid Method Adaptation of the turbidimetric method

FLUORIDE - Reagents: HR - HI-93739-01 (100 tests); HI-93739-03 (300 tests)
LR - HI-93729-01 (100 tests); HI-93729-03 (300 tests)

Fluoride Range Low Range: 0.00 to 2.00 mg/L (as F-) High range: 0.0 to 20.0 mg/L (as F-)
Fluoride Resolution 0.01 mg/L; 0.1 mg/L
Fluoride Accuracy Low Range: ±0.03 mg/L ±3% of reading High Range: ±0.5 mg/L ±3% of reading
Fluoride Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, SPADNS method

HARDNESS, CALCIUM - Reagents: HI-93720-01 (100 tests); HI-93720-03 (300 tests)

Hardness, Calcium Range 0.00 to 2.70 mg/L (as CaCO3)
Hardness, Calcium Resolution 0.01 mg/L
Hardness, Calcium Accuracy ±0.11 mg/L ±5% of reading
Hardness, Calcium Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Calmagite method

HARDNESS, MAGNESIUM - Reagents: HI-93719-01 (100 tests); HI-93719-03 (300 tests)

Hardness, Magnesium Range 0.00 to 2.00 mg/L (as CaCO3)
Hardness, Magnesium Resolution 0.01 mg/L
Hardness, Magnesium Accuracy ±0.11 mg/L ±5% of reading
Hardness, Magnesium Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, EDTA Colorimetric method

HARDNESS, TOTAL - Reagents: HR - HI-93735-02 (100 tests); MR - HI-93735-01 (100 tests); LR - HI-93735-00 (100 tests); HR MR &LR - HI-93735-0 (100 x 3 tests)

Hardness, Total Range Low Range: 0 to 250 mg/L (as CaCO3) Medium Range: 200 to 500 mg/L (as CaCO3) High Range: 400 to 750 mg/L (as CaCO3)
Hardness, Total Resolution 1 mg/L
Hardness, Total Accuracy Low Range: ±5 mg/L ±4% of reading Medium Range: ±7 mg/L ±3% of reading High Range: ±10 mg/L ±2% of reading
Hardness, Total Method Adaptation of the EPA recommended method 130.1

HYDRAZINE - Reagents: HI-93704-01 (100 tests); HI-93704-03 (300 tests)

Hydrazine Range 0 to 400 μg/L (as N2H4)
Hydrazine Resolution 1 μg/L
Hydrazine Accuracy ±4% of full scale reading
Hydrazine Method Adaptation of the ASTM Manual of Water and Environmental Technology, method D1385-88, p-Dimethylaminobenzaldehyde method

IODINE - Reagents: HI-93718-01 (100 tests); HI-93718-03 (300 tests)

Iodine Range 0.0 to 12.5 mg/L (as I2)
Iodine Resolution 0.1 mg/L
Iodine Accuracy ±0.1 mg/L ±5% of reading
Iodine Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, DPD method

IRON - Reagents: HR - HI-93721-01 (100 tests); HI-93721-03 (300 tests)
LR - HI-93746-01 (50 tests); HI-93746-03 (150 tests)

Iron Range Low Range: 0.000 to 1.600 mg/L (as Fe) High Range: 0.00 to 5.00 mg/L (as Fe)
Iron Resolution 0.001 mg/L; 0.01 mg/L
Iron Accuracy Low Range: ±0.01 mg/L ±8% of reading High Range: ±0.04 mg/L ±2% of reading
Iron Method Low Range: Adaptation of the TPTZ Method High Range: Adaptation of the EPA Phenanthroline method 315B, for natural and treated waters

MAGNESIUM - Reagents: HI-937520-01 (50 tests); HI-937520-03 (150 tests)

Magnesium Range 0 to 150 mg/L (as Mg2+)
Magnesium Resolution 1 mg/L
Magnesium Accuracy ±5 mg/L ±3% of reading
Magnesium Method Adaptation of the Calmagite method

MANGANESE - Reagents: HR - HI-93709-01 (100 tests); HI-93709-03 (300 tests)
LR - HI-93748-01 (50 tests); HI-93748-03 (150 tests)

Manganese Range Low Range: 0 to 300 µg/L (as Mn) High range: 0.0 to 20.0 mg/L (as Mn)
Manganese Resolution 1 µg/L; 0.1 mg/L
Manganese Accuracy Low Range: ±0.02 mg/L ±3% of reading High Range: ±0.3 mg/L ±5% of reading
Manganese Method Low Range: Adaptation of the PAN Method High Range: Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Periodate method

MOLYBDENUM - Reagents: HI-93730-01 (100 tests); HI-93730-03 (300 tests)

Molybdenum Range 0.0 to 40.0 mg/L (as Mo6+)
Molybdenum Resolution 0.1 mg/L
Molybdenum Accuracy ±0.3 mg/L ±5% of reading
Molybdenum Method Adaptation of the mercaptoacetic acid method

NICKEL - Reagents: HR - HI-93726-01 (100 tests); HI-93726-03 (300 tests)
LR - HI-93740-01 (50 tests); HI-93740-03 (150 tests)

Nickel Range Low Range: 0.000 to 1.000 mg/L (as Ni) High Range: 0.00 to 7.00 g/L (as Ni)
Nickel Resolution 0.001 mg/L; 0.01 g/L
Nickel Accuracy Low range: ±0.010 mg/L ±7% of reading High Range: ±0.07 g/L ±4% of reading
Nickel Method Low Range: Adaptation of the PAN method High Range: Adaptation of the photometric method

NITRATE - Reagents: HI-93728-01 (100 tests); HI-93728-03 (300 tests)

Nitrate Range 0.0 to 30.0 mg/L (as NO3-- N)
Nitrate Resolution 0.1 mg/L
Nitrate Accuracy ±0.5 mg/L ±10% of reading
Nitrate Method Adaptation of the cadmium reduction method

NITRITE - Reagents: HR - HI-93708-01 (100 tests); HI-93708-03 (300 tests)
LR - HI-93707-01 (100 tests); HI-93707-03 (300 tests)

Nitrite Range Freshwater Low Range: 0 to 600 μg/L (as NO2--N) High Range: 0 to 150 mg/L (as NO2-) Seawater Ultra Low Range: 0 to 200 μg/L (as NO2--N)
Nitrite Resolution Freshwater: 1 μg/L; 1 mg/L Seawater: 1 μg/L
Nitrite Accuracy Freshwater Low Range: ±20 μg/L ±4% of reading High Range: ±4 mg/L ±4% of reading Seawater ±10 μg/L ±4% of reading
Nitrite Method Adaptation of the EPA Diazotization method 354.1

OXYGEN, DISSOLVED - Reagents: HI-93732-01 (100 tests); HI-93732-03 (300 tests)

Oxygen, Dissolved Range 0.0 to 10.0 mg/L (as O2)
Oxygen, Dissolved Resolution 0.1 mg/L
Oxygen, Dissolved Accuracy ±0.4 mg/L ±3% of reading
Oxygen, Dissolved Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Azide modified Winkler method

OXYGEN, SCAVENGER

Oxygen, Scavenger Range 0 to 1000 μg/L (as DEHA) 0.00 to 1.50 mg/L (as Carbohydrazide) 0.00 to 2.50 mg/L (as Hydroquinone) 0.00 to 4.50 mg/L (as ISO-ascorbic acid)
Oxygen, Scavenger Resolution 1 μg/L (DEHA); 0.01 mg/L
Oxygen, Scavenger Accuracy ±5 μg/L ±5% of reading (DEHA)
Oxygen, Scavenger Method Adaptation of the iron reduction method

OZONE - Reagents: HI-93757-01 (100 tests); HI-93757-03 (300 tests)

Ozone Range 0.00 to 2.00 mg/L (as O3)
Ozone Resolution 0.01 mg/L
Ozone Accuracy ±0.02 mg/L ±3% of reading
Ozone Method Colorimetric DPD Method

pH - Reagents: HI-93710-01 (100 tests); HI-93710-03 (300 tests)

pH Range Photometer: 6.5 to 8.5 pH pH electrode: -2.00 to 16.00 pH
pH Resolution Photometer: 0.1 pH pH electrode: 0.1 pH
pH Accuracy Photometer: ±0.1 pH pH electrode: ±0.01 pH
pH Calibration Automatic one or two point calibration with one set of standard buffers available (4.01, 6.86, 7.01, 9.18, 10.01)
pH Temperature Compensation Automatic (-5.0 to 100.0 oC; 23.0 to 212.0 oF); limits reduced based on the pH electrode used
pH CAL Check (electrode diagnostics) clean electrode and check buffer/check probe displayed during calibration
pH Method Photometer: phenol red
pH-mV Range ±1000 mV
pH-mV Resolution 0.1 mV
pH-mV Accuracy ±0.2 mV

PHOSPHATE - Reagents: HR - HI-93717-01 (100 tests); HI-93717-03 (300 tests)
LR - HI-93713-01 (100 tests); HI-93713-03 (300 tests)

Phosphate Range Freshwater Low Range: 0.00 to 2.50 mg/L (as PO43-) High range: 0.0 to 30.0 mg/L (as PO43-) Seawater Ultra Low Range: 0 to 200 μg/L (as P)
Phosphate Resolution Freshwater: 0.01 mg/L; 0.1 mg/L Seawater: 1 μg/L
Phosphate Accuracy Freshwater Low Range: ±0.04 mg/L ±4% of reading High Range: ±1 mg/L ±4% of reading Seawater Ultra Low Range: ±5 μg/L ±5% of reading
Phosphate Method Freshwater Low Range: Adaptation of the Ascorbic Acid method Freshwater High Range and Seawater Ultra Low Range: Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Amino Acid method

POTASSIUM - Reagents: HI-93750-01 (100 tests); HI-93750-03 (300 tests)

Potassium Range 0.0 to 20.0 mg/L (as K)
Potassium Resolution 0.1 mg/L
Potassium Accuracy ±3.0 mg/L ±7% of reading
Potassium Method Adaptation of the Turbidimetric Tetraphenylborate method

SILICA - Reagents: HR - HI-96770-01 (100 tests); HI-96770-03 (300 tests)
LR - HI-93705-01 (100 tests); HI-93705-03 (300 tests)

Silica Range Low Range: 0.00 to 2.00 mg/L (as SiO2) High Range: 0 to 200 mg/L (as SiO2)
Silica Resolution 0.01 mg/L; 1 mg/L
Silica Accuracy Low Range: ±0.03 mg/L ±3% of reading High Range: ±1 mg/L ±5% of reading
Silica Method Low Range: Adaptation of the ASTM Manual of Water and Environmental Technology, D859, Heteropoly Molybdenum Blue method High Range: Adaptation of the USEPA Method 370.1 and Standard Method 4500-SiO2

SILVER - Reagents: HI-93737-01 (50 tests); HI-93737-03 (150 tests)

Silver Range 0.000 to 1.000 mg/L (as Ag)
Silver Resolution 0.001 mg/L
Silver Accuracy ±0.020 mg/L ±5% of reading
Silver Method Adaptation of the PAN method

SULPHATE - Reagents: HI-93751-01 (100 tests); HI-93751-03 (300 tests)

Sulphate Range 0 to 150 mg/L (as SO42-)
Sulphate Resolution 1 mg/L
Sulphate Accuracy ±5 mg/L ±3% of reading
Sulphate Method Turbidimetric - Sulphate is precipitated with barium chloride crystals

ZINC - Reagents: HI-93731-01 (100 tests); HI-93731-03 (300 tests)

Zinc Range 0.00 to 3.00 mg/L (as Zn)
Zinc Resolution 0.01 mg/L
Zinc Accuracy ±0.03 mg/L ±3% of reading
Send your message to this supplier
Send Now

New Original Multi-parameter Benchtop Photometer & pH Meter HANNA HI83300 - In Stock

Ask Latest Price
Delivery Time :
in stock
Model Number :
HI83300
Price :
USD$1598
Packaging Details :
Original packaging
Supply Ability :
10PC
Payment Terms :
L/C, D/A, D/P, T/T, Western Union
Contact Supplier
New Original Multi-parameter Benchtop Photometer & pH Meter HANNA HI83300 - In Stock
New Original Multi-parameter Benchtop Photometer & pH Meter HANNA HI83300 - In Stock
New Original Multi-parameter Benchtop Photometer & pH Meter HANNA HI83300 - In Stock
New Original Multi-parameter Benchtop Photometer & pH Meter HANNA HI83300 - In Stock
New Original Multi-parameter Benchtop Photometer & pH Meter HANNA HI83300 - In Stock
New Original Multi-parameter Benchtop Photometer & pH Meter HANNA HI83300 - In Stock

Mengchuan Instrument Co,Ltd.

Verified Supplier
5 Years
zhejiang, wenzhou
Since 2013
Business Type :
Manufacturer, Distributor/Wholesaler, Agent, Importer, Exporter, Trading Company, Seller
Total Annual :
1000000-5000000
Employee Number :
30~60
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement