The Danfoss VACON NXS00095A5H1SSSA1A2000000 is a complete long-reference configuration from the VACON NXS industrial variable frequency drive series.
The drive is based on the NXS00095 current rating for three-phase 380-500 VAC systems. It is positioned around a 9 A low-overload current rating and approximately 4 kW motor power at 400 VAC. For higher-overload operation, the corresponding motor positioning is approximately 3 kW.
The A5H1SSSA1A2000000 configuration should be retained in full because the A5 enclosure, H EMC configuration, brake-chopper code, SSS hardware and control arrangement affect replacement compatibility.
| Complete Model | NXS00095A5H1SSSA1A2000000 |
| Base Model | NXS00095 |
| Series | VACON NXS |
| Product Type | Industrial Variable Frequency Drive |
| Input Voltage Family | Three-phase 380-500 VAC; confirm nameplate |
| Low-Overload Current | Approximately 9 A |
| Low-Duty Motor Rating | Approximately 4 kW at 400 VAC |
| High-Duty Motor Rating | Approximately 3 kW; verify application |
| Mechanical Frame | FR4 |
| Enclosure Code | A5; verify exact IP protection |
| EMC Code | H |
| Brake Code | 1; verify braking resistor compatibility |
| Hardware Code | SSS |
| Control Configuration | A1A2000000; verify installed control assembly |
| Supply Status | Regional availability varies; confirm before quotation |
The NXS00095A5H1SSSA1A2000000 is suitable for pumps, fans, conveyors, mixers, packaging equipment and other compact industrial machines using compatible three-phase motors.
The motor full-load current and overload requirement must be checked. A 4 kW motor with heavy starting torque or frequent acceleration may require selection according to the lower high-duty rating.
The A5 protected-enclosure configuration must be compared with the original mounting, ventilation, cable entry and environmental requirements.
Confirm the complete NXS00095A5H1SSSA1A2000000 type code before ordering. A drive described only as NXS00095 may have a different enclosure, EMC, brake or control configuration.
Back up all parameters and record the motor data, control mode, frequency limits, ramps, current limits, digital-input functions, relay outputs and analog references.
Inspect and test used units for fan condition, DC-bus stability, inverter output, keypad operation and terminal functionality.
Search formats include NXS00095A5H1SSSA1A2000000 and NXS00095-A5H1SSS-A1A2000000.
Related base ratings include NXS00075, NXS00125 and NXS00165. Other NXS00095 configurations may use different enclosure or hardware codes and should be verified separately.
Shortened marketplace references must not replace the complete original nameplate during quotation.
Please provide the complete type designation, motor nameplate, supply voltage, load type, enclosure requirement, parameter backup, braking arrangement and terminal wiring.
Product condition, firmware, exact configuration, functional testing and delivery time must be confirmed before quotation.