Over-current recovery conditions: charging recovery or disconnecting the load
Short circuit recovery conditions: charging recovery or disconnecting the load
Charge:
Single battery overcharge voltage: 4.25V ± 0.015V
Overcharge recovery voltage of single battery:4.15V±0.015V
Overcharge delay time:0.5S-1.0S
Continuous charging current:20A
Charging overcurrent protection:50A
Charger Voltage:21V(Recommended)
Balanced Voltage:4.13V±0.015V
Balanced current:42MA current:42MA
Charging temperature protection:0℃~50℃
Discharge temperature protection:-20℃~73℃
Activation method:
If you find no voltage output, please activate the protection board as follows
① Short the B- and P-wires once.
② Charge activation (recommended)
Working power consumption: ≤20uA
Conduction internal resistance of the main circuit: ≤10mΩ
Temperature range: -40~80°C