General
 >> A system for all your applications requiring a high level of dependability: 
 ~~ Electrical distribution and motor control. 
 ~~ A modular structure.
 ~~ For low-voltage switchboards, designed to meet local standards, practices and requirements. 
 A multi-function range
 >> Type D: Distribution switchboards up to 6300 A
 >> Type DC: Power factor correction column
 >> Type Mf: Fixed-type motor-control centres up to 6300 A
 >> Type Mw: Withdrawable-type motor-control centres up to 6300 A
 >> Type Ms: Variable-speed drives and starters column 
 >> Type C: Cubicles up to 630 A. 
 A modular system
 >> Standardized components.
 >> Fast manufacturing.
 >> Easy modifications. 
 Functional design
 1) Rationalized dimensions and layout inside the switchboard.
 2) Reduced footprint.
 3) Easy power and auxiliary connections .
 4) Easy installation upgrading at a controlled cost. 
 5) An intelligent system, ready to integrate devices containing advanced protection and communication 
 functions for electrical distribution and motor control. 
 Compliance to standards
 >> Compliance with international standards: IEC 60439-1 / VDE 0660 part 500.
 >> DIN 41-488 / BS 5486 / EN 60 439-1. 
 >> Seismic withstand: Uniform Building code, California Building code.
 Electrical Characteristics
 >> Rated insulation voltage: 1000 VAC
 >> Rated operational voltage: 690 VAC
 >> Rated impulse withstand voltage: 12 KV
 >> Overvoltage category: IV
 >> Degree of pollution: 3
 >> Frequency: 400 Hz, up to 400 Hz
 Main busbars rated current
 1. Main busbars Single busbars Double busbars
 2. Rated current up to 4000 A up to 6300 A
 3. Rated peak withstand current 63, 105 187 kA 220 kA
 4. Rated short-time current 30, 50 85 kA r ms / 1 s 100 kA r ms / 1 s
 Surface Protection 
 >> External surface protection Epoxy powder polymerized at high temperature. 
 Standard colors 
 >> RAL 9002 (grayish white) / RAL 7016 (graphite grey).
| Rated voltage of main circuit( V) | AC 380( 400, 660) | |
| Rated voltage of auxiliary circuit( V) | AC 220 380( 400) DC 110, 220  |  		|
| Rated frequency( Hz) | 50( 60) | |
| Rated insulation voltage( V) | 660( 1000) | |
| Rated current ( A) | Horizontal busbar | < =4000 | 
| Vertical busbar | 1000 | |
| Rated short time withstand current of busbar( kA/1s) | 50, 80 | |
| Rated peak withstand current of busbar( kA/0.1s) | 105, 176 | |
| Power frequency testing voltage (V/1min) | Main circuit | 2500 | 
| Auxiliary circuit | 1760 | |
| Busbar | 3-phase and 4-wire | A. B. C. PEN | 
| 3-phase and 5-wire | A. B. C. PE. N | |
| Protection degree | IP3L0. IP4L0 | |
| Dimensions | 2200x (600 800 1000)x600(800 1000) | |