6HP AC Air Source Heat Pump for Home Air Conditioning Machine
Quick Details
1.Compared with electric water heaters, it maximizes energy saving. The cost of use is only 1/4 of that of electric water heaters. Compared with traditional gas water heaters, it does not consume any gas fuel. The cost of use is only 1/3 of that of gas water heaters.
2. High automation, the control is same easy as AC unit, no need watching
3.It could be connected with more enders, e.g. AC fans, radiator, underfloor coil.
Model data
| Model | SLNA-017Ycode name.pdf |
| Compressor capacity | 6HP |
| Function | Heating and Cooling |
| Electricity | 380V-3N-50Hz |
| Working conditions | ℃ | -25~~+45 |
| Data | Heata | Nominal capacity | KW | 12 |
| Input power | KW | 4.55 |
| COP | / | 2.4 |
| Heating IPLV(H) | 2.7 |
| Coolb | Nominal capacity | KW | 14 |
| Input power | KW | 5 |
| COP | / | 2.5 |
| Cooling IPLV(C) | 2.7 |
| A7W35c | KW/COP | 19.5/4.21 |
| A2W35 | KW/COP | 27/3.60 |
| A-7W35 | KW/COP | 21.5/2.8 |
| A-15W55 | KW/COP | 19.7 /1.94 |
| A-20W45 | KW/COP | 18.1/2.02 |
| Max. running currency | A | 25 |
| Compressor quantity | set | 2 |
| Refrigerant/charging quantity kg | / | R22/4.8 |
| Air blow type | / | Side |
| Water pipe diameter | mm | G1.2〞 |
| Rating flow | m³/h | 3.2 |
| Water side pressure loss | kPa | ≤45 |
| Noise level | dB(A) | 62 |
| Overall dimensions(L×W×H) | mm | 1120×440×1360 |
| Weight | kg | 130 |
a: Nominal heating conditions: ambient dry bulb temperature-12℃, wet bulb temperature-14℃, outlet water temperature 41℃, water flow 0.172 * nominal heating capacity
b:Nominal refrigeration conditions: ambient dry bulb temperature 35℃, outlet water temperature 7℃, water flow 0.172 * nominal cooling capacity
c:A7W35 working condition: inlet air temperature 7℃, outlet water temperature 35℃
Products Advantages
- Suitable for environmental temperature:-25℃ to +45 ℃ /-13℉ to 113 ℉
- Large-area hydrophilic aluminum heat exchangers increase the heat production.The four-row tube V-shaped arrangement has high heat exchange efficiency and uniform wind speed distribution.It adopts 9.52*0.35 internal thread high-efficiency heat exchange copper tube and 3.1mm large-format hydrophilic aluminum fins with better hydrophobicity; it improves the operating efficiency during frosting and reduces the number of defrosting.
-
The optimized long flow path design and wide expansion of the expansion throttle ensure uniform distribution of refrigerant in low temperature environments. Ensure even frosting, complete defrosting, strong heating and efficient operation
- 35% more powerful than other products, long heating time and less defrosting time
- Quality Components such as Copeland compressor, Danfoss valves
- Pay attention to details such as every stainless-steel screw has cushion to prevent from water corrosion
- Multi-throttle channel design is accurate.
-
Multiple energy-saving devices in a single system, precise control of refrigerant flow, enabling the unit to maximize heat/cooling capacity and maximum energy efficiency in various working environments, reducing operating costs
- 100% finished products testing
Learn more about air source heat pump
.Safety
There is a safety hazard of electric leakage in the electric water heater. The gas water heater has the problem of gas poisoning. Compared with the two water heaters, the air energy water heater passes through the medium heat exchange, avoiding the direct contact between the electric heating element and the water, thus solving the electric water heater. There are hidden dangers of leakage, and secondly, because the raw material is air, the possibility of gas explosion or gas poisoning in gas water heaters is also excluded, which makes people more comfortable and worry-free.