| 1/2" RF Coaxial Cable NO.7101106 |
| |
| Construction Parameters: |
| Inner Conductor | 4.80±0.05mm Copper Clad Aluminum Wire |
| Insulation | 12.00±0.20mm Foamed PE |
| Outer Conductor | 13.80±0.15mm Annular Corrugated Copper Tube |
| Jacket | 15.70±0.20mm PE, Black |
| Jacket Thickness | >0.80mm |
| | |
| Electrical Characteristics: |
| Capacitance | 76 pF/m |  |
| Impedance | 50 ±2 Ω |
| Velocity of Propagation | 87% |
| Peak Power Rating | 40 KW |
| Max. Operating Frequency | 8.8 GHz |
| Insulation Resistantce | >10000 MΩ.km |
| DC Breakdown Voltage | 6000 V |
| Jacket Spark Test Voltage | 8000 Vrms |
| Inner Conductor DC Resistance | 1.62 Ω/km |
| Outer Conductor DC Resistance | 4.30 Ω/km |
| Shielding Attenuation | ≥120dB |
| VSWR | |
| 800MHz-1000MHz | ≤ 1.13 |
| 1700MHz-2700MHz | ≤ 1.15 |
| 2700MHz-4000MHz | ≤ 1.20 |
| 4000MHz -5000MHz | ≤ 1.20 | | | |
| PIM | | | | |
| Intermodulation (3rd order,2*20W) | ≤ - 160 dBc | | | |
| | | | | | | | | |
| | | | | | | | | |
| | | | | | | | | |
| Mechanical Properties: |
| Bending Radius (Single Bend) | 55 mm |
| Bending Radius (Repeated Bend) | 130 mm |
| Bending moment | 6.5 Nm |
| Flat plate crush strength | 8 N/mm |
| Tensile Strength | 950 N |
| | | | | | | | | |
| Mechanical Properties: |
| | PE Jacket | LSZH Jacket |
| Installation Temperature | -40℃ to +60 ℃ | -20℃ to+60 ℃ |
| Operating Temperature | -55℃ to +85 ℃ | -30℃ to +80 ℃ |
| Storage Temperature | -70℃ to +85 ℃ | -30℃ to +80 ℃ |
| | | |
| Attenuation(20℃): |
| Frequency (MHZ) | Attenuation (dB/100m) | Average Power (KW) |
| 200 | 3.18 | 2.41 |
| 450 | 4.88 | 1.57 |
| 800 | 6.64 | 1.16 |
| 900 | 7.08 | 1.09 |
| 1800 | 10.35 | 0.75 |
| 2000 | 10.98 | 0.70 |
| 2200 | 11.58 | 0.67 |
| 2500 | 12.44 | 0.62 |
| 2700 | 13.02 | 0.59 |
| 3000 | 13.80 | 0.56 |
| 3500 | 15.15 | 0.51 |
| 4000 | 16.40 | 0.47 |
| 5000 | 18.62 | 0.42 |
| 6000 | 20.70 | 0.37 |
| | | |
| Maximum attenuation value shall be 105% of the nominal attenuation value |
| | | | | | | | | |
| Standards and Order Informations: |
| Fire Resistant | IEC 60754-1,-2; IEC 60332-1,-2; IEC 61034-1,-2; IEC 60332-3-24 |
| RoHS | Compliant RoHS 2011/65/EU |
| Delivery time | Normally 25 days after received the deposit. |
| Marking | HELLOSIGNAL 1/2" RF COAXIAL CABLE ××× M |