Specifications
Model Number :
5-06
Company Type :
Manufacturer
Supply Ability :
300 Set/Sets per Month centrifugal fan and axial fan manufacturer
Applicable Industries :
Manufacturing Plant, Construction Works , Energy & Mining, Industrial Dust Collector System
After-sales Service Provided :
Field Installation, Commissioning And Training
Price :
$500-1000
Voltage :
380V
Delivery Time :
35days(To be negotiated)
System Type :
Single Inlet, Overhang Type
Certification :
CE/ISO9001/ISO45001
MOQ :
1
Packaging Details :
1.export wooden case packing 2.bare package with steel pallet 3.other export package
Lubrication :
Oil bath lubrication
Power source :
Three Phase AC Motor
Mounting :
FREE STANDING
bearing :
ZWZ, SKF, FAG, NSK,Can Be Specified
Brand Name :
SIMO BLOWER
Warranty :
1 Year
Place of Origin :
China
Description
Boiler Equipped with Primary Air Fan
The primary air fan is one of the three main types of fans in a coal-fired power plant boiler, forming the core power equipment of the boiler flue gas system together with the forced draft fan (secondary air fan) and induced draft fan. Its main task is to provide sufficient high-pressure primary air to the boiler combustion system, undertaking key functions such as fuel delivery, drying, sealing, and combustion support.
The primary air fan outlet air is divided into hot and cold paths: hot primary air is heated by an air preheater and then sent to the pulverizing system for drying and carrying pulverized coal; cold primary air is used to regulate the temperature of the air-coal mixture. After mixing, both types of air together transport the pulverized coal to the furnace and provide oxygen for the initial combustion stage. In circulating fluidized bed boilers, the primary air also needs to be divided into multiple paths to achieve functions such as bed fluidization, coal feeding, and sealing.
As of 2026, primary air fans mostly adopt a centrifugal design, featuring high pressure head, large flow rate, and high stability, and are widely used in thermal power generation, industrial boilers, and incineration systems.
Boiler equipped with primary air fan
Working Principle
Centrifugal primary air fans mainly consist of an impeller, a volute casing, a main shaft, bearing housings, and a coupling. When the motor drives the impeller to rotate at high speed through the coupling, the air between the blades is thrown towards the outer edge of the impeller under centrifugal force, increasing its kinetic and pressure energy. After the gas enters the volute casing, the flow velocity decreases as the flow cross-section gradually expands, and some of the kinetic energy is further converted into static pressure energy. The air at the center of the impeller is discharged, creating a certain degree of vacuum. Air outside the intake port is continuously drawn in under atmospheric pressure—as the impeller continues to rotate, air is continuously drawn in and expelled, achieving continuous gas delivery.
Core Functions
  • Pulverized Coal Heating and Drying: Hot primary air (approximately 300-350℃), heated by the air preheater, is sent to the pulverizing system for preliminary heating and drying of the pulverized coal, reducing its moisture content and improving combustion efficiency.
  • Pulverizing System Sealing: In some boilers, sealing air is directly drawn from the primary air header and introduced into equipment such as the coal feeder, effectively preventing pulverized coal leakage.
  • Initial Fuel Combustion Support: After thorough mixing of pulverized coal and primary air in the burner, the mixture is sent to the furnace, providing the necessary oxygen for ignition and initial combustion.
Product Parameters
The following data represents partial performance specifications. If you require specific parameters not listed, please contact us for customized design service.
Boiler equipped with primary air fan
Series no. 6-06 series Feature selection
Performance Impeller diameter 400-2800mm
Rotation speed ≤3000rpm
Pressure range 1706-8265Pa
Flow range 2752-498507㎥/h
Structure Blade type Backward, Straight, Aerofoil type
Impeller support SWSI, DWDI, Overhung type
Lubrication method Oil bath, grease, lubrication oil station
Cooling method Air cooling, Water cooling, Oil cooling
Driven mode Direct driven, Coupling driven, Belt driven
Boiler equipped with primary air fan
Installation & Manufacturing
Boiler equipped with primary air fan
Our manufacturing facility operates more than 300 sets of processing and testing equipment with an annual production capacity of 10,000 units. We maintain strict quality control throughout production to ensure zero-error manufacturing and can meet emergency delivery requirements to guarantee your project timelines.
Boiler equipped with primary air fan
Packaging & Shipping
Boiler equipped with primary air fan
Contact Us
Boiler equipped with primary air fan Contact Our Engineering Team for Custom Fan Solutions
Send your message to this supplier
Send Now

Boiler equipped with primary air fan

Ask Latest Price
Watch Video
Model Number :
5-06
Company Type :
Manufacturer
Supply Ability :
300 Set/Sets per Month centrifugal fan and axial fan manufacturer
Applicable Industries :
Manufacturing Plant, Construction Works , Energy & Mining, Industrial Dust Collector System
After-sales Service Provided :
Field Installation, Commissioning And Training
Price :
$500-1000
Contact Supplier
video
Boiler equipped with primary air fan
Boiler equipped with primary air fan
Boiler equipped with primary air fan
Boiler equipped with primary air fan
Boiler equipped with primary air fan

Xinxiang SIMO Blower Co., Ltd.

Verified Supplier
7 Years
henan, xinxiang
Since 1955
Business Type :
Manufacturer
Total Annual :
3500000-25000000$
Employee Number :
200~300
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement