Designed for flue gas conditions after waste incineration, this industrial instrument provides continuous online measurement of SO2, NO, NO2, CO, CO2, O2, NH3, HCl, H2O, flow rate, pressure, temperature, particulate matter, and other components. Additional measurement components can be integrated based on user requirements.
Primarily applied in municipal waste incineration, hazardous waste incineration, medical waste incineration, sludge incineration, biomass boilers, thermal power plants, steel mills, and other high-temperature, high-humidity environments.
| Parameter Category | Specification |
|---|---|
| Working Condition | |
| Power Supply | 220VAC, <3kW |
| Sweeping Gas | (0.4~0.6) MPA compressed air |
| Ambient Temperature | -20ºC~55ºC |
| Performance Index | |
| Light Path Length | 760mm |
| Range | 0~100 (ppm or mg/m³) (range-adjustable) |
| T90 Response Time | <300 seconds |
| Reading Error | ≤ ±5% (nominal value) |
| Repeatability | ≤ ±2% F.S |
| Drift | ≤ ±2.5% F.S |
| Protection Level | IP55 |
| Preheating Time | 120min |
| Functional Parameters | |
| Digital Output | RS485 |
| Analog Output | 4-20 mA maximum load of 500Ω |
| Switch Output | Load capacity: AC/DC 24V/1A; Backpack signal, low instrument wind pressure, abnormal temperature alarm, etc. (customizable) |
| Sample Gas Temperature | <600ºC |
| Other Parameters | |
| Sample Gas Pressure | Atmospheric pressure of ±5 KPA |
| Sampling Traffic | 2-3L/min |
| Ambient Temperature | -10~55ºC |
| Ambient Pressure | 70~120kpa |
| Outline Dimension | (950H×1160L×325W)mm |
| Weight | 120kg |
| No. | Name | Model and Specification | Quantity | Unit |
|---|---|---|---|---|
| 1 | Pre-processing Cabinet | Pre-treatment and control devices | 1 | Set |
| 1.1 | Analysis Cabinet | 950H×1160L×325W mm | 1 | Set |
| 1.2 | Electromagnetic Valve | DC24V, normally closed | 2 | Set |
| 1.3 | Injection Pump | 8L/min | 1 | Set |
| 1.4 | High-temperature Precision Filter | 0.2um | 1 | Set |
| 1.5 | Control Circuit | Including automatic sampling, back-blowing, and temperature control | 1 | Set |
| 1.6 | High Temperature Cut-off Valve | BTB-DN10, with a pneumatic valve | 1 | Set |
| 2 | Analytic System | HCL, CO analyzer | 1 | Set |
| 3 | Heated-type Sampling Probe | AG-TT07 | 1 | Set |
| 4 | Sampling Heat Tracing Pipeline | 60W/m | 3 | Set |
| 5 | Spare Part | See the list of spare parts | 1 | Set |