ZR-YJV22 flame-retardant cross-linked polyethylene steel-tape armored cable conforms to the national standard GB/T 12706.1~12706.4-2020 "Cross-linked Polyethylene Insulated Power Cables". Its flame-retardant performance strictly complies with the GB/T 19666 standard, is consistent with the international IEC 60502 series standards, and complies with EU CE LVD and EMC directives. It also meets domestic fire safety regulatory filing and cross-border public infrastructure bidding and customs clearance standards.
All finished cable reels undergo third-party type testing in a nationally accredited electrical laboratory and are equipped with ZR series-specific flame-retardant professional testing items:
Each large-scale fire protection project order comes with a complete set of official filing documents stamped by the factory, provided free of charge:
All documents fully comply with fire safety supervision filing, construction supervision review, municipal pipe gallery acceptance, hospital/airport public building fire safety inspection, and overseas EPC tender document review requirements.
Voltage Coverage: Low voltage 0.6/1kV, medium voltage 8.7/10kV, 8.7/15kV, high voltage 26/35kV
Customizable Conductor Layout: Single-core/Double-core/Three-core/Four-core/Five-core Category 2 T2 oxygen-free copper core cable, cross-section range 16mm²~630mm², suitable for small branch lighting circuits to large substation main feeders.

When ordinary non-flame-retardant YJV22 cables are bundled and laid in underground shopping malls, integrated utility tunnels, and hospital basements, they create continuous fire spread paths, failing fire safety inspections. ZR-YJV22 employs a flame-retardant modified XLPE insulation + flame-retardant outer sheath double-layer fire protection system, passing national bundle-shaped flame-retardant tests. It is a basic mandatory cable type required by fire safety regulations for all public buildings and industrial enclosed cable trenches with fire risks. Electrical design engineers prioritize ZR-YJV22 in large commercial, medical, and municipal utility tunnel projects to avoid rework and cable replacement due to failed fire safety inspections.
Compared to ZC-VV22 PVC insulated flame-retardant cable, which has a long-term allowable temperature of only 70℃, ZR-YJV22 XLPE insulated cable can operate stably at 90℃ for extended periods, increasing its continuous current carrying capacity by 30% for the same cross-sectional dimensions. For applications with high peak power consumption and significant heat generation, such as large shopping malls, data center auxiliary power supplies, and heavy industrial backbone lines, this characteristic effectively avoids the risk of cable overheating during peak loads while maintaining complete flame-retardant safety performance, achieving the dual advantages of high transmission efficiency and fire resistance.
The double-steel-belt mechanical damage-resistant structure is suitable for high-risk laying scenarios such as municipal trunk road crossings, mountain rock foundation trenches, large underground utility tunnels, and dense cable trenches in the basements of commercial complexes. It effectively avoids insulation damage commonly caused by foundation settlement, temporary construction vehicle traffic, and friction from underground sharp rocks in urban power grid upgrades and commercial real estate projects, thereby reducing the general contractor's subsequent cable replacement and line maintenance costs.
The ZR-YJV22 series covers low-voltage, medium-voltage, and high-voltage levels, with diverse conductor structures from single-core to five-core, and cross-sectional specifications ranging from small branch lighting to large substation main feeders. It can simultaneously meet the application needs of low-voltage power distribution in underground shopping malls, medium-voltage trunk lines in chemical industrial parks, and high-voltage incoming lines in municipal central substations. EPC contractors can complete the procurement of all flame-retardant armored cables for an entire commercial or industrial park project with just one supplier, thereby simplifying procurement classification, incoming material inspection, and on-site temporary warehouse management.
The ZR dedicated flame-retardant XLPE cable automated production line is equipped with real-time online monitoring equipment to monitor the uniformity of flame-retardant raw material mixing, insulation layer thickness, and steel tape armor winding tightness. The flame-retardant performance and electrical parameters of each batch are strictly controlled within standard tolerances, eliminating the risk of inconsistent flame-retardant grades or unstable current carrying capacity between different cable reels, and avoiding delays in fire protection acceptance due to unqualified individual batches of cables.

The electrical design of a core commercial complex in a certain area adopted a large quantity of ZC-grade ZR-YJV22 four-core and three-core series flame-retardant armored cables as the main trunk lines buried in all basements for air conditioning, elevators, and lighting. The construction area was a fully enclosed underground parking lot and commercial activity area, belonging to a Class B fire hazard area, with dense cable laying. Double-layer steel tape armor can resist foundation settlement and mechanical impact from decoration construction; the flame-retardant performance of the ZR series cables has fully passed the third-party testing of the municipal fire department. Our factory provided a complete flame retardant test report and a full set of certification documents, which passed the acceptance tests of the fire and power departments on the first attempt, without the need for additional sampling tests. After four years of continuous full-load operation (including peak summer and winter seasons), no cable overheating or hidden faults occurred, reducing the daily electrical inspection labor costs for the property by 70%.
A fine chemical manufacturing park constructed a fully enclosed underground integrated utility tunnel, uniformly selecting ZB flame-retardant modified ZR-YJV22 8.7/15kV three-core cables as all medium-voltage buried trunk lines within the tunnel. Due to the enclosed space of the tunnel, natural heat dissipation is poor, and the surrounding soil contains residual weakly acidic chemical wastewater. A reinforced anti-corrosion and flame-retardant outer sheath and a full copper strip shielding structure were adopted to effectively resist internal high-temperature accumulation and underground chemical corrosion, while simultaneously suppressing electromagnetic interference to nearby chemical monitoring optical cables. Standardized, complete fire protection certification documents accelerated the park's safety supervision and review process, ensuring uninterrupted power supply to the synthesis production equipment 24 hours a day, year-round.
A Grade A hospital in a certain region underwent expansion and power grid renovation. ZC flame-retardant ZR-YJV22 8.7/10kV three-core armored cables were laid underground for the incoming lines of two large-capacity dedicated transformers. The hospital's power system is a mandatory uninterruptible power supply system, and the underground cable trenches are adjacent to a medical waste storage area, posing a potential risk of open flame. The ZR flame-retardant cross-linked polyethylene (XLPE) structure forms a carbonized protective layer in the event of accidental ignition, extending the safe maintenance time for medical equipment; the double-layer steel tape armor prevents insulation damage caused by underground pipeline maintenance. Stable batch electrical parameters eliminated the risk of localized overheating during peak power consumption periods for medical equipment, reducing annual underground line maintenance and equipment downtime losses by more than 83%.

Each delivery includes a complete set of officially certified materials stamped by the factory free of charge:
These documents fully meet the requirements for fire safety supervision filing, construction supervision review, chemical industrial park safety acceptance, and overseas public infrastructure EPC customs clearance, avoiding delays in the construction cycle of large-scale industrial and commercial projects due to incomplete flame-retardant certification materials.
Our professional ZR flame-retardant cable R&D team provides free consultation services:
For bulk orders from large shopping malls, chemical industrial parks, and municipal integrated utility tunnels, professional engineers provide remote video on-site construction guidance, promptly helping construction teams solve technical problems suchs as cable bundling and laying, underground cable protection, and fire protection acceptance.
We have established long-term, exclusive strategic supply partnerships with top-tier T2 oxygen-free copper smelters and certified high-efficiency flame-retardant cross-linked polyethylene (XLPE) raw material manufacturers, completely eliminating the use of recycled copper and inferior non-flame-retardant plastic raw materials. Each batch of products undergoes full-bundle flame-retardant and high-voltage laboratory performance testing before delivery; the mixing ratio of flame-retardant materials, insulation layer thickness, and steel tape armor wrapping tightness are monitored online in real time throughout the process to ensure the flame-retardant safety and stable electrical performance of all cable reels, eliminating fire safety hazards in dense bundling projects.
Our specially designed intelligent automated production workshop for ZR-YJV22 cables maintains ample inventory of mainstream low-voltage/medium-voltage standard specifications, enabling immediate shipment. For key commercial real estate, chemical industrial parks, and municipal utility tunnel EPC projects, we prioritize the production of customized high-grade flame-retardant, corrosion-resistant, and low-temperature modified ZR-YJV22 cables to fully meet the urgent construction schedule requirements of fire protection engineering contractors.
Each cable reel is printed with a unique production batch number, production date, voltage rating, and core specifications, enabling full traceability from raw material supply to finished product delivery. Large orders from major commercial, medical, and chemical industrial parks are eligible for extended factory quality assurance. If, during the warranty period, non-human-caused damage results in defects in the manufacturing process such as flame retardant failure, insulation aging, or armor layer damage, we will provide free replacement and full cable replacement services to minimize the risk of large-scale power outages and reduce fire safety hazards for the purchaser and long-term EPC project partners.
ZR-YJV22 flame-retardant cross-linked polyethylene (XLPE) steel-tape armored power cable is the standard flame-retardant armored cable specified for commercial, medical, chemical, and municipal integrated pipeline power distribution projects with stringent fire safety requirements worldwide. It is widely recognized and recommended by fire protection design institutes, municipal power grid companies, and global public infrastructure EPC contractors. Its unique ZR bundled flame-retardant composite insulation structure, 90℃ high-temperature resistance and high current-carrying capacity, and all-around double-layer steel tape mechanical damage resistance enable this cable to adapt to various complex enclosed underground fire-resistant laying environments, reasonably balancing the initial project procurement investment and long-term fire safety maintenance costs for project owners and contractors.
Our factory integrates independent R&D of flame-retardant medium and low voltage cables, intelligent automated production, and a fully standardized flame-retardant high-voltage testing laboratory. We focus on providing stable, fully fire-compliant, and cost-effective ZR-YJV22 series armored cables to global commercial real estate, public healthcare, chemical, and municipal utility tunnel infrastructure users. We support long-term, stable, and bulk supply cooperation for various fire-sensitive underground power distribution projects.