Product Description
Specification
| Product model |
JK-B15A24S |
| Dimensions |
232.3x191x42 MM |
| Active balancing current |
0.8~15A adjustment |
| Cell voltage range |
1V~5V±5MV |
| Cell voltage difference after balancing |
≤5MV |
| Power supply range |
40V~100V |
| Operating temperature |
-30℃~90℃ |
| Balancing method |
Energy transfer active balancing technology |
| Balancing start condition |
Balancing starts automatically when the voltage difference exceeds the trigger value (settable), and starts automatically when it is >10MV by default |
| Applicable battery string number |
2~24 battery packs |
| Applicable battery types |
Support all types of batteries such as Li-ion, iron lithium, lead acid, LTO, super capacitors, etc. |
| Balancing cascade |
Support, applicable to battery packs with more than 24 strings, theoretically unlimited cascading |
| Bluetooth communication function |
Standard Bluetooth communication, optional 485, CAN |
| Power consumption |
Balancing state 10MA@100V, non-balanced state 6MA@100V |
Comment Faulty Causes And Treatment
| S/N |
Fault phenomenon |
Cause analysis |
Troubleshooting method |
| 1 |
The power indicator light is off |
The balancer does not supply power normally |
Check whether the power pin on the connector is connected to the power supply. |
| 2 |
The APP cannot search for the device |
The APP is far away from the device |
It is advisable to keep the distance range around 2~3m |
| 3 |
The APP prompts that the number of cell settings does not match the set value |
The number of cell settings is wrong or the connection of the balance line is abnormal |
Check whether the number of cells settings is the same as the number of connected batteries. |
| 4 |
The APP prompts that the resistance of the balance line is too large |
The line resistance from the battery to the connector is too large |
Check whether there is poor contact between the battery monomer and the connector, otherwise please replace the wire. |
| The above are common faults, possible causes and solutions. If the fault is still not eliminated, please contact E&J Technology Co., Ltd. to solve it. |