Overview
Prismatic Cell Charging And Discharge Machine
Model: 5V160A
| No. | Item | RCDS-5V160A | ||
|---|---|---|---|---|
| 1 | Main channels | 500 CH (MES Server Compatibility) | ||
| 2 | Channels working mode | Independently | ||
| 3 | Main channel working mode | Charge: CC, CV, CCCV, no voltage or current impact when CC transfer to CV Discharge: CD, CP, CR Still | ||
| Main channel test cutoff condition | Time, total voltage, total current, capacity, -ΔV, Vcell, RSOC, etc. | |||
| 4 | Main channel Voltage | Single channel test range | 0V-5V | |
| Min. discharge voltage | 0.1V | |||
| Accuracy | ±(0.05%FS+0.05%RD) | |||
| Resolution | 1mV | |||
| Main channel Current | Single channel test range | ±150A | ||
| Min. output current | 200mA | |||
| Accuracy | ±(0.05%FS+0.05%RD) | |||
| Resolution | 1mA | |||
| Current start response time | <50ms | |||
| Time | Resolution | 100 ms | ||
| Power | Output power | Single channel continuous working power 500W | ||
| Stability | ±(0.1%FS+0.1%RD) | |||
| Auxiliary channel parameter cutoff function | Main channel step can be set to stop or jump when auxiliary channel signal reach to a certain condition. | |||
| 5 | Communication | LAN | ||
| 6 | Control program | Support data protection when power off, continue testing caused of power cutoff or manually stop and revise step parameter online. | ||
| Users can set protection condition, include minimum voltage, maximum voltage, minimum current, maximum current, etc. | ||||
| Users can set auxiliary channel protection condition, including minimum voltage, maximum voltage, maximum temperature, minimum temperature. | ||||
| Cycle time | Max. 9,999 | |||
| Programmable step | Max. 9,999 | |||
| Nested loop | Max. 10 layers | |||
| Step time range | No limit, support h, min, s | |||
| Data record | Time≥1S, voltage≥1mV, current ≥1mA | |||
| Program feature | Each step has one or multiple exit | |||
| 7 | Data display | Cycle list | Circulation number. Charge/discharge capacity, efficiency, power and average voltage, etc. | |
| Process list | Process number, working mode, process time, capacity, power, DIR, medium voltage, cut-off voltage, cut-off current, etc. | |||
| Detail list | Record number, system time, cumulative time, voltage, current, energy, power, cell temperature, etc. | |||
| 8 | Data export | Data can be exported as EXCEL, TXT or diagram. Provide charge discharge efficiency, charge discharge curve, voltage, capacity, current-time characteristic curves, etc. | ||
| 9 | Data saving | Save as files | ||
| 10 | Curves type | X-coordinate: total time, charge discharge capacity, cycle time | ||
| Y-coordinate: total voltage, current, capacity, power, cell temperature | ||||
| 11 | Software protection | Power off data protection, power resume continue testing, OVP, ODP, OCP, UCP, OTP, capacity protection, abnormal voltage trend protection, abnormal current trend protection, abnormal current fluctuation protection, abnormal voltage fluctuation protection, abnormal charging voltage increase rate protection, abnormal discharge current decrease rate protection | ||
| Hardware protection | Power off, open circuit and short circuit protection. Reverse or wrong connection protection, OCP, OVP, OTP. | |||
| Warning function | Switch off automatically under emergency, shutdown when power off, load connect and disconnect automatically. | |||
| 12 | Sampling terminals | Four-polar sampling. Crocodile clip or other clips. | ||
| 13 | Energy consumption | Discharge power feedback to grid | ||
| 14 | Cooling method | Forced Fan-cooled | ||
| 15 | Safety grade | In accordance with EN60950, GB4943 | ||
| Voice | Test voice by IEC62040-3 and voice is less than 70dBA. Sound level meter should be accordance with Ⅰtype in IEC804, Accuracy should be better than ±0.5dB. | |||
| IP grade | IP20 | |||
| Thunder proof | Reach GB17626 2-pole lightning protection requirements. | |||
| 16 | Repair | Modularized structure. Can be replaced or repair with spare parts. Free during warranty period. | ||
| 17 | Software update | For lifetime until hardware incompatible. | ||
Advantages