For IEC Testing of residual voltage after plug disconnect.
The KP-1060 disconnects the line at the voltage peak and analyzes results to the requirements of various Standards, allowing quick results.
Scope output for viewing decay waveform.
Presets for IEC 61010-1, IEC62368-1, IEC 60601-1 and IEC60335-1.
| Minimum/Maximum Test Voltage | 0-300V |
| Maximum Test Current | 10A |
| Fuse: | 10A, 250V, time delay, 1-¼" x ¼" |
| Probe Impedance | = 100MΩ, < 25pF |
| AC Peak Detection Accuracy | EUT disconnect within 5% of supply voltage peak |
| Test Time Range | 0.50 - 99.0 Seconds |
| Test Time Accuracy | ±1% for times ≥ 1 second, +/- 10ms for < 1 second. |
| Voltage Setting Resolution | 0.1V |
| Voltage Meter Accuracy | ±1.5% of instrument measuring range |
| Frequency | 50-60Hz. |
| Rated Input Voltage | 220V 50/60HZ |