Climatic Test Chambers
Key Specifications
| Attribute |
Value |
| Environmental Requirements |
Clean environment with no pollutant sources, TVOC ≤500μg/m³ |
| Temperature Range |
10~40℃ (high temperature cleaning up to 250℃) |
| Humidity Range |
40~70% R.H (20℃~30℃) |
| Pressure |
10±5pa |
Primary Applications
- Determine environmental variables' impact on material/product release rates and properties
- Classify materials/products based on release characteristics
- Develop and validate indoor air pollution models
- Assess indoor air quality (IAQ) using pollutant data and models
Compliance Standards
Chinese Standards: GB 18580, GB 18584, GB 18587, HJ571-2010, HJ566-2010
International Standards: ENV717-1, EN13419-1, ISO12219-4, VDA-276
Reference Standards: ASTM D5116-97, ASTM D6330-98, ASTM D1333-96
Technical Parameters
| Product Model |
V-50 |
V-100 |
V-250 |
V-500 |
V-1000A |
V-1000B |
V-2000 |
| Chamber Volume (W×D×H cm) |
56×30×30 |
63×40×40 |
70×60×60 |
102×70×70 |
158×80×80 |
91×100×110 |
200×110×90 |
| Starting Power |
5kW |
6kW |
8kW |
10kW |
15kW |
15kW |
20kW |
| Operating Power |
3kW |
3.4kW |
5kW |
6kW |
7kW |
7kW |
9kW |
Performance Specifications
| Temperature Fluctuation |
±0.3℃ |
| Temperature Deviation |
±0.5℃ |
| Humidity Fluctuation |
±2.5% R.H |
| Humidity Deviation |
±3% |
| Air Exchange Rate |
0.2~5/h ±5% (optional 0.2~3/h ±5%) |
| Air Velocity |
0.1m/s - 0.3m/s |
| Recovery Rate |
>80% for formaldehyde, octanol, 4-phenyl cyclohexene, dodecane, tetradecane |
| Clean Air System |
Standard configuration |
| Background Concentration |
Single VOC <2μg/m³, TVOC <20μg/m³ |
Power Requirements: 380V/50Hz three-phase power supply (4/5 wiring system)