IEC 60335-2-17 Three-Sided Metal Screen
Height:
900 mm
Width:
450 mm
Depth:
300 mm
Testing Configuration & Procedure
This metal screen testing apparatus is designed for evaluating heating elements and internal wiring samples according to IEC 60335-2-17 standards.
- Accommodates samples of at least 150 mm in length
- Features a grid inclined at 45° angle for testing
- Grid constructed with parallel 0.6 mm diameter wires spaced 20 mm apart
- Sample placement perpendicular to horizontal wires, centered between wires
- Secondary grid of similar size placed on sample with horizontal wires offset 10 mm from primary grid
- Both grids remain parallel to the sample and properly aligned