Neware 8Channel Coins Battery Cycle Tester Three Electrodes Material Analyzer
1 . The design of the uA current unit plays a vital role in the field of current accurate measurement , which is more convenient and more accurate .
2 . The lower range is able to output current low as 5uA , which can tell the subtle difference of various materials such electrodes , electrolyte , separator , etc .
3 . Generally , magnetoelectric galvanometer can achieve uA level , electromagnetic galvanometer can achieve mA level .
4 . It mainly focuses on battery research and development instituions and universities .
5 . Neware 5V10mA / 20mA / 50mA is born for coin cell test , formerly its 5V1mA this modle . Students and researchers in universities and institutes just love this product , its the real star on their mind .
6 . dQ / dV differential capacity curve , the peak on the curve indicates that there is a voltage plateau on the charge and discharge curve , and different peaks represent different electrochemical reactions .
| Power | Per Channel Output Power | 0.25W |
| Stop current | Range 1 , 2uA Range 2 , 0.01mA Range 3 , 0.02mA | |
| Stop current | Range 1 , 2uA Range 2 , 0.02mA Range 3 , 0.04mA | |
| Stop current | Range 1 , 2uA Range 2 , 0.05mA Range 3 , 0.1mA | |
| Stability | 0.1percent of FS | |
| Data Recording | Record Condition | Min Time - 100mS |
| Min Voltage - 10mV | ||
| Min Current - Range 1 , 2uA Range 2 , 0.01mA Range 3 , 0.02mA | ||
| Min Current - Range 1 , 2uA Range 2 , 0.02mA Range 3 , 0.04mA | ||
| Min Current - Range 1 , 2uA Range 2 , 0.05mA Range 3 , 0.1mA | ||
| Record Frequency | 10Hz | |
| Charge | Charge Mode | CCCharge , CVCharge , CCCVCharge , CPCharge |
| End Conditon | Voltage , Current , Relative Time , Capacity , -deltaV | |
| Discharge | Discharge Mode | CCD , CPD , CRD |
| End Condition | Voltage , Current , Relative Time , Capacity | |
| Pulse | charge | CCC , CPC |
| Discharge | CCD , CPD | |
| Min Pulse Width | 500ms | |
| Automated Switch | Automated swith from charge to discharge for each pulse | |
| End Condition | Voltage, Test Time | |
| Cycle | Loop Measure Range | 65535 times |
| Max Steps Per Loop | 254 | |
| Nested Loop | Nested loop Function , Max Support 3 Layers | |
| Protection | Software Protection | Power - down Data Protection |
| Off - line Testing Function | ||
| Setting Protection Condition,Setting Parameter - Low Voltage limit , Upper Voltage limit , Low Current limit , Upper Current limit , Delay Time | ||
| IP protection level | Protection level IP20 | |
| Voltage and Current Testing Sample | 4 - wire connecting | |
| Database | MySQL Database | |