Neware Regenerative Battery Pack Cycle Tester 200V200A Canbus DBC Test System
 
CE - 6000 series regenerative battery module pack tester designed for secondary battery charge / discharge test , specialized in testing high power module / pack battery . 
1 . It has a high dynamic response speed , high accuracy . 
2 . Also , the regenerative function is included to greatly reduce power consumption during the discharge test .
 
The CE - 6000 series battery testing system supports channels to expand . Multi - channel can be chosen. Each module is 120V50A , and you can add the module according to your real test requirement . Each module has built - in parallel channels . The parallel function aims to increase the max current in real tests , saving the cost to expand the large range . The parallel function also is safety and reliability . Furthermore , withing using powerful BTS80 software which independent develop by Neware , you can test the driving simulation test , HPPC test , DCIR test , capacity test , and other tests required high sample data rate, high accuracy , and high response speed .
 
CE - 6000 series battery testing system , Power battery simulation test, rate test . Cycle life test . Power, capacity and energy detection . 
 
Virtual configuration of power battery pack , charge and discharge curve fitting, battery consistency detection and evaluation . 
 
High rate charge and discharge ability detection . 
 
Power battery , energy storage battery series module detection , monomer voltage, monomer temperature monitoring - high voltage equipment .
 
 
Charge  | Charge modes | Constant current , Constant voltage , Constant current and voltage , Constant power | 
| Cut - off condition | Main channel - Voltage , Current , delta Time , Capacity , - delta V | |
Discharge  | Discharge modes | Constant current , Constant voltage , Constant power , Constant resistance | 
| Cut - off condition | Main channel - Voltage , Current , delta Time , Capacity | 
| Simulated Condition | Charge modes | Constant current , Constant power | 
| Discharge modes | Constant current , Constant power | |
| Cut - off condition | Time , Line Number | |
| Continuous switching Chg and Dischg | One simulation step can realize a continuous switching from charging to discharging | |
| Limit step number | 1 million | |
Protection  | Software protection  | Power - off data protection | 
| Off - line operation mode | ||
| User - defined protection conditions , such as upper and lower limited current / voltage , delay time , temperature , etc . | 
| Channels feature | Constant Current Source and Constant Voltage Source with Independent pairs of Closed-loop Structure | 
| Channels control mode | Independent control | 
| Noise | ≤65dB | 
| Database | MySQL | 
| Communication | TCP/IP | 
| Operating system | Windows 7/8/10 64bit | 
 