Energy Feedback 100V 60A 8-Channel Battery Aging Machine for Battery Pack Manufacturing
Product Description
ACEY-BA10060-8 Energy Feedback Battery Charging and Discharging Testing Machine is designed for battery pack aging, capacity testing, charge-discharge performance evaluation, and temperature characteristic testing. It supports lithium-ion, LiFePO4, lead-acid, NiMH, and NiCd battery packs. With 8 independent channels, adjustable charging and discharging currents from 100mA to 60A, and a voltage range of up to 100V, it enables programmable multi-step testing, real-time data monitoring, curve analysis, and Excel data export for battery manufacturing and quality control.
Test Items
Software Step Settings Requirements
Equipment Features
Main Technical Parameter
|
NO |
Item |
Function requirement |
||
|
1 |
Channel |
8 |
||
|
2 |
Action Mode |
Completely independent |
||
|
3
|
Main channel work mode |
Charging: constant current and constant voltage charging CCCV.&CC Discharge: constant current discharge CD.& CP Resting, stopping |
||
|
Main channel test abort condition |
Time, voltage, current, capacity, etc |
|||
|
4
|
Voltage of main channel |
Votage range of charge |
0V~100V |
|
|
|
Votage range of discharge |
10V~100V |
||
|
|
Accuracy |
±(0.05%RD+0.05%FS) |
||
|
|
Resolution |
1mV |
||
|
Current of main channel |
Maximum output current |
Discharge & Charge 60A |
||
|
|
Minimum output current |
100mA |
||
|
|
Accuracy |
±(0.05%RD+0.05%FS) |
||
|
|
Resolution |
1mA |
||
|
Power |
Output |
Single channel continuous operation maximum power 6000W |
||
|
Auxiliary channel parameter cut-off function |
The main channel step can be set to stop or switch when the auxiliary channel signal reaches certain conditions. |
|||
|
5
|
Control program |
Support for power-down data protection, support for power outages, manual stopping and succession of tests from data files. |
||
|
|
Safety protection conditions can be set, including: lower voltage limit, upper voltage limit, lower current limit, upper current limit, voltage and current trend. |
|||
|
|
Auxiliary channel protection conditions can be set and parameters can be set including: upper voltage limit, lower voltage limit, upper temperature limit and lower temperature limit. |
|||
|
|
Cycle times |
Max 9999 |
||
|
|
Work step time unit |
h,min,s are available |
||
|
|
Data logging |
Min 5S |
||
|
6
|
Data display method |
Loop List |
cycle number, charge/discharge capacity, charge/discharge efficiency, charge/discharge energy, charge/discharge average voltage, etc. |
|
|
|
Process List |
process serial number, operation mode, process time, capacity, energy, median voltage, termination voltage, termination current, etc. |
||
|
|
Detailed list |
There are record serial number, system time, accumulated time, voltage, current, energy, power, etc. |
||
|
7 |
Data export method |
The data can be exported to EXCEL and chart files, which can provide a variety of data analysis curves such as charging and discharging efficiency, charging and discharging curves, voltage, capacity, current time characteristics, etc., and the curves can be imported into EXCEL. |
||
|
8 |
Curve Type |
X coordinate: total time, charging and discharging capacity, cycle times, etc., can be set freely. |
||
|
Y coordinate: total voltage, current, capacity, single body temperature, charge/discharge capacity, single body voltage, etc., can be set freely. |
||||
|
9 |
Software protection |
Power-down data protection, power-off pause renewal, over-voltage and over-discharge protection, over-current and under-current protection, capacity protection, over-temperature protection, abnormal current fluctuation protection, abnormal charging voltage rise rate protection, abnormal discharge voltage fall rate protection. |
||
|
Hardware protection |
Battery reversal, over-current protection, over-voltage protection, short-circuit protection. |
|||
|
Alarm function |
The hardware has functions such as emergency cut-off switch, automatic shutdown after power failure, and automatic load connection and disconnection. |
|||
|
10 |
Output wire |
Four-wire connection mode with separate current and voltage lines. |
||
|
11 |
Maintainability |
Modular structure, available spare parts, spare parts for timely replacement, repair, free of charge during the warranty period. |
||
|
12 |
Test channel and battery pack connection method |
Alligator clamp |
||
|
13 |
Equipment testing environment and technical requirements |
Single cabinet requires 30KW 380V three-phase four-wire power configuration, ventilation and dry plant Working environment: temperature -10℃~40℃ / humidity: 10%~90% |
||
Product Display
FAQ
Q1: What battery types can this battery charging and discharging tester test?
The ACEY-BA10060-8 Battery Charging and Discharging Tester supports aging and performance testing of lithium-ion, lithium iron phosphate, lead-acid, nickel-metal hydride, and nickel-cadmium battery packs.
Q2: How many battery packs can the tester test simultaneously?
The ACEY-BA10060-8 Battery Charging and Discharging Tester features 8 fully independent channels, allowing up to 8 battery packs to be tested simultaneously with independently configured test parameters.
Q3: What are the voltage and current ranges of this battery tester?
The ACEY-BA10060-8 Battery Charging and Discharging Tester supports charging voltages up to 100V, a discharge voltage range of 10V to 100V, and adjustable charging and discharging currents from 100mA to 60A.