▋Indoor Node Controller
The indoor node controller aggregates all parking space information in the area, encodes and uploads the data to the indoor central controller, and simultaneously receives the available parking space information data from the indoor central controller and then transmits it down to the indoor zone controllers. When used in large-scale networking, the indoor node controller can effectively solve the problem of insufficient device capacity of the indoor central controller; when applied in parking lots with complex structures, it can effectively ensure the stability of system communication.
▋Technical Specifications
| Equipment Name |
Indoor Node Controller |
| Product Model |
P-KO2N |
| Specification & Dimension |
320×260×90mm |
| Net Weight |
2.74Kg |
| Shell Material |
Galvanized Steel Sheet with Plastic Spraying |
| Power Consumption |
≤2W |
| Node Capacity |
25 units |
| Working Voltage |
AC 110~240V |
| Working Temperature |
-30℃ ~ +75℃ |
| Ambient Humidity |
≤90%RH (Non-condensing) |
| Communication Mode |
2 CAN Channels @20kbps |
| Communication Distance |
≤1000m |
| Equipment Composition |
Power Supply, Control Board, Shell, Air Switch |
▋Product Features
- Adopts an internationally advanced 32-bit ARM processor with a full industrial-grade design to ensure the stability and reliability of the product.
- All system controllers support remote upgrade, facilitating system maintenance and upgrade to meet user needs at all times.
- Adopts an industrial-grade CAN bus communication design with stable and reliable signal transmission, covering a maximum distance of 1 kilometer.
- The device is equipped with short-circuit, overvoltage and overload protection functions to prevent electrical damage to relevant equipment caused by wiring errors during construction.
- The whole unit features an industrial design and has passed rigorous tests for ESD, lightning strike, surge, electrical fast transient burst and other disturbances, effectively ensuring the reliable operation of the equipment.
- Supports group management of zone control, enabling optimized management of network communication and realizing functions such as data conversion and data grouping processing.
- Supports one-click firmware upgrade on the server side for quick replacement and expansion of the latest program functions.