The LBS type cantilever beam load cell is engineered for precision and durability. Constructed from high-quality alloy steel, this single-ended load cell utilizes a steel ball for force transfer, ensuring easy installation and excellent compatibility across various weighing systems.
| Parameter | Value |
|---|---|
| Maximum capacity | 600kg, 1t, 2t, 3t, 5t, 10t, 20t |
| Sensitivity | 2.0±0.004 mV/V (600kg, 5t, 10t/20t); 3.0±0.004 mV/V (1, 2, 3t) |
| Accuracy class | C3 (600kg-3t); C2 (5t-20t) |
| Combined error | 0.02%F.S. (C3); 0.023%F.S. (C2) |
| Supply voltage | 5 ~ 15 (DC/AC) |
| Input resistance | 380 ~ 440 Ω |
| Output resistance | 349 ~ 355 Ω |
| Insulation resistance | ≥5000 MΩ |
| Operating temperature | -30 ~ +70 ℃ |