Amaxpower UPS Battery 12V 24Ah Solar Deep Cycle Sealed Rechargeable Gel Battery for Energy Battery Storage (12V 24Ah)
12V 24ah SMF VRLA Gel Rechargeable Solar Energy Storage Battery VRLA Sealed Lead Acid Battery UPS Battery
Amaxpower 12V 24Ah Solar Deep Cycle AGM Battery UPS Battery
AMAXPOWER GS Series (VRLA Lead Acid Battery) is free maintenance lead acid batteries, are designed with AGM technology, high performance plates and electrolyte to gain extra power out for common power backup system applications widely used in the fields of UPS, Security and Emergency lighting system.
Applications of Sealed Lead Acid Batteries : (12v 24ah/33ah/38ah/40ah/45ah deep cycle battery solar energy storage battery.
Uninterruptible power supplies (UPS); Emergency Lighting Systems; Alarm Systems, Computers; Fire & security systems; Telecommunication systems; Inverter; Solar powered systems; Power Tools; Communication equipment; Electronic cash registers; Electronic test equipment; processor based office machines; Control equipment; Electric powered bicycle and wheelchairs; Geophysical equipment; Marine equipment; Medical equipment; Portable cine & video lights; Television& video recorders; Vending machines; Toys; Geophysical Equipment; Vending Machines ; Other standby or primary power supplies.
Specification
Nominal Voltage | 12V (6 cells) | |
Nominal Capacity | 24Ah@10 hour-rate | |
Dimension | Length | 165±2(6.49 inches) |
Width | 126±2(4.96 inches) | |
Height | 174±2(6.85 inches) | |
Total Height | 174±2(6.85 inches) | |
Weight | Approx. 7.6kg (17.2lbs) | |
Reference Capacity (25°C/77°F ) | 20 hour rate (1.3A) | 26Ah |
10 hour rate (2.4A) | 24Ah | |
5 hour rate (4.32A) | 21.6Ah | |
3 hour rate (6.4A) | 19.2Ah | |
1 hour rate (15.6A) | 15.6Ah | |
Max. Discharge Current (25°C/77°F) | 156A (5S) | |
Internal Resistance | Full charged at 25℃(77°F): Approx. 15mΩ | |
Charge (Constant Voltage) (25°C/77°F) |
Cycle Use |
Voltage: 14.4-15.0V Initial Charging Current: Less than 7.2A |
Float Use | Voltage: 13.6-13.8V | |
Operating Temperature Range | Discharge | -20~50°C |
Charge | 0~50°C | |
Storage | -20~50°C | |
Nominal Operating Temperature Range | 25°C ±3°C(77±3°F) | |
Capacity affected by Temperature (20 hour rate) |
40°C(104°F) | 102% |
25°C(77°F) | 100% | |
0°C(32°F) | 85% | |
-15°C(5°F) | 65% | |
Self-Discharge (25°C/77°F) | After 3 month | 91% |
After 6 month | 82% | |
After 12 month | 64% | |
Container Material | ABS Plastic |
-Electric Powered Vehicles -Golf Cars and Buggies
-Wheel Chairs -Power Tools
-Electric Powered Toys -Control System
-Medical Equipments -UPS Systems
-Solar and Wind -Emergency Systems