12V 55Ah/60Ah/65Ah/70Ah/80Ah/90Ah Long Life Gel Solar Battery For UPS Backup(12V 55Ah)
12V55Ah UPS Solar Battery Deep Cycle Gel Battery For Solar Energy System and Power System
Amaxpower patented High Temperature Solar Deep Cycle long life Gel battery, best choice to work in hot/cold temperature sites and maintain long service life over 18years. HD series of 12V GEL deep cycle batteries are recognized as the most reliable and high quality battery system in the industry. They are designed with advanced patented GEL technology, Long service life designed with 15-20 years.
Certificates: ISO9001/14001/18001 ; CE/IEC 60896-21/22 / IEC 61427 /UL Approved
Applications of Deep Cycle Gel Batteries:
Chinese Best Quality Solar GEL Battery Applications:
Φ Communication equipment Φ Telecommunication control equipment Φ Emergency lighting systems Φ Electric power systems Φ Power station
Φ Nuclear power station Φ Solar powered and wind powered systems Φ Load leveling and storage equipment Φ Marine equipment Φ Power generation plants
Φ Alarm systems ΦUninterruptible power supplies and stand-by power for computers Φ Medical equipment Φ Fire and security systems Φ Control equipment
Φ Stand-by electric power.
Specification
Nominal Voltage | 12V (6 cells) | |
Nominal Capacity | 55Ah@10 hour-rate | |
Dimension | Length | 230±2(9.06 inches) |
Width | 138±2(5.43 inches) | |
Height | 211±2(8.30 inches) | |
Total Height | 229±2(9.01 inches) | |
Weight | Approx. 16.2kg (35.7lbs) | |
Reference Capacity (25°C/77°F ) | 20 hour rate (2.9A) | 58Ah |
10 hour rate (5.5A) | 55Ah | |
5 hour rate (9.9A) | 49.5Ah | |
3 hour rate (15.0A) | 45.0Ah | |
1 hour rate (35.5A) | 35.5Ah | |
Max. Discharge Current (25°C/77°F) | 355A (5S) | |
Internal Resistance | Full charged at 25℃(77°F): Approx. 8.0mΩ | |
Charge (Constant Voltage) (25°C/77°F) |
Cycle Use |
Voltage: 14.4-15.0V Initial Charging Current: Less than 16.5A |
Float Use | Voltage: 13.6-13.8V | |
Operating Temperature Range | Discharge | -20~50°C |
Charge | 0~50°C | |
Storage | -20~50°C | |
Nominal Operating Temperature Range | 25°C ±3°C(77±3°F) | |
Capacity affected by Temperature (20 hour rate) |
40°C(104°F) | 102% |
25°C(77°F) | 100% | |
0°C(32°F) | 85% | |
-15°C(5°F) | 65% | |
Self-Discharge (25°C/77°F) | After 3 month | 91% |
After 6 month | 82% | |
After 12 month | 64% | |