Specifications
MOQ :
1000M
Delivery Time :
1-15days
Life Span :
30 years
Payment Terms :
L/C, T/T, Western Union, MoneyGram
Voltage :
Low/Medium/High Voltage
Service :
ODM OEM Accepted
Dimensions :
0.5--1000mm2
Model Number :
ACSR
Price :
Negotiable
Application :
Overhead
Certification :
ISO CCC
Place of Origin :
Henan
Supply Ability :
200 tons per day
Name :
Aluminium Conductor Steel Reinforced
Brand Name :
Sanwu
Packaging Details :
New Wooden drum, reel, circle, or according to customers request
Description

ACSR Bare Conductor 25/4 Aluminum Conductor Steel Reinforced Wire for Overhead Power Lines

This ACSR bare conductor, designated 25/4, is manufactured with stranded aluminum wires concentrically layered over a galvanized steel core. The steel core carries the mechanical load, while the aluminum strands provide the conductive path, making the conductor suitable for overhead power transmission and distribution lines. The 25/4 designation refers to the stranding configuration of the conductor, indicating the number of aluminum and steel wires used in its construction. The cable is supplied in bare form for direct installation on insulators and support structures. Its composite design helps control sag across overhead spans, and the galvanized core offers protection against atmospheric corrosion during outdoor service.

ACSR Conductor Standards
* ASTM B-232 * BS 215
* CSAC 61089 * AS/NZS 3607
* DIN 48204 * IEC 61089
* GB/T 1179 * JIS C3110

Specifications

Code Size (AWG/MCM) Number of Strands(mm) Weight(kg/km) Rated Strength(kg)
Rose 4 7*1.96 58.3 399
Iris 2 7*2.47 92.7 611
Pansy 1 7*2.78 117 740
Aster 2/0 7*3.5 186 1375

ACSR Bare Conductor 25/4 Aluminum Conductor Steel Reinforced Wire for Overhead Power Lines

The Characteristics of ACSR:

  1. Galvanized Steel Reinforced Core
    The core is zinc-coated to resist atmospheric corrosion while providing the tensile strength required for overhead spans beyond the capability of all-aluminum conductors.

  2. Concentric Stranded Aluminum Layers
    Electrical-grade aluminum wires are stranded in concentric layers around the core, forming a uniform conductive path and allowing the conductor to be reeled, strung, and tensioned with standard overhead line equipment.

  3. Bare Overhead Construction
    Supplied without insulation for direct mounting on insulators and support hardware, with the aluminum surface forming a natural oxide layer that resists weathering in most outdoor environments.

  4. 25/4 Stranding Designation
    The conductor is identified by its 25/4 stranding configuration, which defines the ratio of aluminum to steel wires and determines its mechanical and electrical characteristics.

  5. Balanced Mechanical and Electrical Performance
    The aluminum-to-steel ratio is selected to balance current-carrying capacity with sag and tension behavior, supporting reliable performance across transmission and distribution applications.

ACSR Bare Conductor 25/4 Aluminum Conductor Steel Reinforced Wire for Overhead Power Lines

Applications

  1. Overhead Power Transmission Lines
    Used as a bare conductor on transmission routes where low sag and high tensile strength are required.

  2. Medium-Voltage Distribution Networks
    Installed on pole lines supplying industrial, commercial, and residential loads at moderate current levels.

  3. Long-Span Crossings
    Selected for river, valley, and roadway crossings where the steel core provides the mechanical margin needed to control sag.

  4. Substation Connections
    Applied for jumper leads and bus connections within switchyards and transformer bays.

  5. Reconductoring and Capacity Upgrades
    Used to replace aging conductors on existing overhead lines, improving transmission capability without altering tower or pole structures.

ACSR Bare Conductor 25/4 Aluminum Conductor Steel Reinforced Wire for Overhead Power Lines

Our technical team can optimize the design and customize the production of wires according to your specific needs.

Packing & Delivery:
Wooden drums with dimater 1.1m, 1.2m, 1.6m, 1.8m and 2.2m etc.

Aluminium conductors are commonly wound onto wooden or steel reels, which provide protection during transport and handling.

According to customers request.
ACSR Bare Conductor 25/4 Aluminum Conductor Steel Reinforced Wire for Overhead Power Lines

Pay attention to the following steps during installation:

  1. Tension control: It is recommended to control the tension at 20% -30% of the rated value to avoid excessive stretching.
  2. Sag adjustment: Adjust the sag according to the ambient temperature, generally within the range of 1% -3% span.
  3. Connection processing: Use specialized crimping tools, and the recommended crimping pressure is 20-30MPa.

More Products:
ACSR Bare Conductor 25/4 Aluminum Conductor Steel Reinforced Wire for Overhead Power Lines

Customers Visit

ACSR Bare Conductor 25/4 Aluminum Conductor Steel Reinforced Wire for Overhead Power Lines

At our factory, we take pride in fostering strong relationships with our international clients. Foreign customers visited our facility to gain firsthand experience of our production processes and quality standards. During their visit, they were impressed by our state-of-the-art manufacturing capabilities, commitment to quality, and the dedication of our skilled workforce.

All wires and cables are produced in strict accordance with EC, SAA CCC, ISO, ASTM, DIN, VED, JIS and other standard. As one manufacturer, here we can also provide customized services for various special types of cables according to customer needs.
We always adheres to the enterprise spirit of "quality wins customers, reputation creates benefits", and sincerely welcomes friends from all over the world to visit our company and cooperate.

FAQ
1. ARE YOU A FACTORY OR A TRADER?
We are the factory, you are welcome to visit the factory.
2. WHAT IS YOUR PAYMENT TERMS?
100% in advance & 30% deposite, 70% balance before shipment.(Credit card,T/T).
3. DO YOU PROVIDE SAMPLES FREE OF CHARGE?
Yes,but the shipping cost should be on buyer's account.
4. DO YOU PROVIDE AFTER-SALES SERVICE?
Yes.If you find that the goods have quality problems,Please submit proof file, picture video to us,We will investigate andgive you a satisfactory solution.
We always believe that the success of our customers is our success. The steel cored aluminum stranded wire we provide is not just a roll of metal wire, it is a "bridge of trust" that we have built together with you, flowing with current. We look forward to hearing your specific project challenges and providing you with the most valuable solutions.
Send your message to this supplier
Send Now

ACSR Bare Conductor 25/4 Aluminum Conductor Steel Reinforced Wire for Overhead Power Lines

Ask Latest Price
Watch Video
MOQ :
1000M
Delivery Time :
1-15days
Life Span :
30 years
Payment Terms :
L/C, T/T, Western Union, MoneyGram
Voltage :
Low/Medium/High Voltage
Service :
ODM OEM Accepted
Contact Supplier
video
ACSR Bare Conductor 25/4 Aluminum Conductor Steel Reinforced Wire for Overhead Power Lines
ACSR Bare Conductor 25/4 Aluminum Conductor Steel Reinforced Wire for Overhead Power Lines
ACSR Bare Conductor 25/4 Aluminum Conductor Steel Reinforced Wire for Overhead Power Lines

Luoyang Sanwu Cable Co., Ltd.,

Verified Supplier
7 Years
henan, luoyang
Since 2016
Business Type :
Manufacturer, Exporter
Total Annual :
10000000-30000000
Employee Number :
50~200
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement