Specifications
Supply Ability :
100 tons per day
Name :
Aluminium Conductor Cable
Model Number :
Quadruplex Triplex Duplex Service Drop
MOQ :
2000M
Delivery Time :
25days
Sample :
Free samples
Payment Terms :
T/T, L/C
Size :
1.5mm 2.5mm 4mm 6mm 10m 16mm 25mm 35mm, customizable
Type :
High/medium/low voltage
Price :
Negotiate
Insulation :
PVC, PE, XLPE, HDPE
Application :
Industrial
Certification :
ISO
Place of Origin :
Henan, China
Packaging Details :
Wooden drum, steel reel
Brand Name :
Luoyang Sanwu
Description
Durable Overhead Aluminum Bare Conductor Cable Soild Power Electrical Wire AAC AAAC ACSR Stranded Aluminum Wire

We supply the range of durable overhead aluminum bare conductors includes AAC (All Aluminium Conductor), AAAC (All Aluminium Alloy Conductor), and ACSR (Aluminium Conductor Steel Reinforced) types, available in both solid and stranded constructions for overhead power transmission and distribution. AAC conductors are manufactured from EC‑grade aluminium 1350‑H19 wires, offering a lightweight solution for short to medium spans. AAAC conductors use aluminium‑magnesium‑silicon alloy wires, providing higher tensile strength for longer spans and heavier loading. ACSR conductors combine outer aluminium strands with a galvanized or aluminium‑clad steel core, delivering maximum mechanical reinforcement for long‑span and high‑tension applications. Solid conductors are supplied in smaller sizes for service drops and short connections, while stranded conductors are available across a wide cross‑sectional range for main feeders and transmission lines. All conductors are supplied in bare form, suitable for direct installation on insulators and support structures in outdoor overhead environments.

Standard
ASTM, IEC, GB, NFC 33-209

A: Duplex Service Drop

Code*Word Phase conductor Bare Neutral Message Nominal lay Length Weight Per
1000 ft.(lbs.)
Allo wable Amp acitles
Size
(A WG)
Stranding Insul
Thick(Mils)
Size
(AWG)
Stranding Rated
Strength
(lbs.)
inches XLP POLY XLP POLY
AAC Neutral-messenger
Pekingese 6 1 45 6 7 563 10.36 61 61 85 70
Collie 6 7 45 6 7 563 10.36 64 64 85 70
Dachshund 4 1 45 4 7 881 10.36 92 92 115 90
Spaniel 4 7 45 4 7 881 10.36 96 96 115 90
Doberman 2 7 45 2 7 1350 14.88 147 147 150 120
Malemute 1/0 9 60 1/0 7 1990 14.88 234 234 205 160


B.Triplex Service Drop

Code*Word Phase conductor Bare Neutral Message Nominal lay Length Weight Per
1000 ft.(lbs.)
Allo wable Amp acitles
Size
(A WG)
Stranding Insul
Thick(Mils)
Size
(AWG)
Stranding Rated
Strength
(lbs.)
inches XLP POLY XLP POLY
AAC Neutral-messenger
Pateela 6 7 45 6 7 563 14.88 103 103 85 70
Oyster 4 7 45 4 7 881 14.88 154 154 115 90
Clam 2 7 45 2 7 1350 20.58 233 233 150 120
Murex 1/0 7 60 1/0 7 1990 20.58 374 374 205 160
Purpura 1/0 9 60 1/0 7 1990 20.58 368 368 205 160
Nassa 2/0 7 60 2/0 7 2510 25.42 462 462 235 185
Melita 3/0 17 60 3/0 19 3310 29.97 562 562 275 215
Portunus 4/0 18 60 4/0 19 4020 29.97 696 696 315 245
Nannynose 336.4 19 60 336.4 19 6146 38.79 1118 1118 420 325


C. Quadruplex Service Drop
Used to supply 3 phase power, usually from a pole- mounted transformer, to the user's service head where connection to the service entrance cable is made. To be used at voltages of 600 volts or less phase to phase and at conductor temperatures not to exceed 75°C for polyethylene insulated conductors or 90°C for crosslinked polyethylene (XLP) insulated conductors.
Construction
Conductors are concentrically stranded, compressed 1350-H19 aluminum. Insulated with either polyethylene or XLP crosslinked polyethylene. Neutral messengers are concentrically stranded AAC/AAAC/ACSR. One conduc
tor is manufactured with an extruded ridge for phase identification.

Code*Word Phase conductor Bare Neutral Message Nominal lay Length Weight Per
1000 ft.(lbs.)
Allo wable Amp acitles
Size
(A WG)
Stranding Insul
Thick(Mils)
Size
(AWG)
Stranding Rated
Strength
(lbs.)
inches XLP POLY XLP POLY
AAC Neutral-messenger
Clydessdale 4 1 45 4 7 881 20.58 198 198 100 80
Pinto 4 7 45 4 7 881 20.58 211 211 100 80
Mustang 2 7 45 2 7 1350 25.42 318 318 135 105
Criollo 1/0 9 60 1/0 7 1990 25.42 503 503 180 140
Percheron 2/0 11 60 2/0 7 2510 29.97 619 619 205 160
Hanovarian 3/0 17 60 3/0 19 3310 35.18 764 764 235 185
Oldenburg 4/0 18 60 4/0 19 4020 35.18 945 945 275 210
Lippizaner 336.4 19 80 336.4 19 6146 38.79 1519 1519 370 280

Features:

  • Multiple Conductor Types – includes AAC for standard conductivity, AAAC for enhanced strength‑to‑weight ratio, and ACSR for maximum tensile reinforcement, allowing selection based on span length and loading conditions.
  • Solid and Stranded Options – Solid conductors are available for smaller sizes and short connections, while stranded conductors are supplied in concentric‑lay constructions for flexibility and uniform current distribution in larger sizes.
  • Aluminium and Alloy Construction – Conductors are manufactured from EC‑grade aluminium or aluminium‑magnesium‑silicon alloy, with steel core options for ACSR, providing material selection based on electrical and mechanical requirements.
  • Standardised Stranding Configurations – Stranding patterns and conductor diameters conform to recognised overhead conductor specifications, ensuring compatibility with standard fittings and connectors.

Durable Overhead Aluminum Bare Conductor Cable Soild Power Electrical Wire AAC AAAC ACSR Stranded Aluminum Wire

Applications:

  • Low and Medium Voltage Distribution – AAC and AAAC conductors installed on pole lines serving residential, commercial, and light industrial areas with moderate span lengths.

  • High‑Voltage Transmission Lines – ACSR conductors used on long‑span transmission routes where high tensile strength and low sag are required.

  • Service Drops and Customer Connections – Solid or stranded conductors in smaller sizes used for overhead connections from distribution lines to building entry points.

  • Rural Electrification Backbones – AAC and AAAC conductors deployed along agricultural routes and remote areas, where lightweight construction and adequate strength are advantageous.

  • Substation Jumpers and Bus Connections – Stranded conductors used for internal connections within substation switchyards and transformer bays.

Durable Overhead Aluminum Bare Conductor Cable Soild Power Electrical Wire AAC AAAC ACSR Stranded Aluminum Wire
Producing Process:

Durable Overhead Aluminum Bare Conductor Cable Soild Power Electrical Wire AAC AAAC ACSR Stranded Aluminum Wire
Packing & Delivery:
Wooden drums with dimater 1.1m, 1.2m, 1.6m, 1.8m and 2.2m etc.;

Aluminium conductors are commonly wound onto wooden or steel reels, which provide protection during transport and handling.
20GP, 40GP and 40HQ containers

Standard Export Packaging for Aluminium Conductor Cables
All our aluminium conductor cables are packaged according to international export standards, ensuring complete protection during long-distance transportation. Each cable drum is constructed from premium plywood or steel materials, reinforced with heavy-duty steel rims and multiple protective layers. We include waterproof wrapping, shock-absorbent edge protectors, and custom-branded external covers to maintain product integrity from our factory to your site.

Durable Overhead Aluminum Bare Conductor Cable Soild Power Electrical Wire AAC AAAC ACSR Stranded Aluminum Wire

Customers Visit:

Durable Overhead Aluminum Bare Conductor Cable Soild Power Electrical Wire AAC AAAC ACSR Stranded Aluminum Wire

All wires and cables are produced in strict accordance with EC, SAA CCC, ISO, ASTM, DIN, VED, JIS and other standard. As one manufacturer, here we can also provide customized services for various special types of cables according to customer needs.
We always adheres to the enterprise spirit of "quality wins customers, reputation creates benefits", and sincerely welcomes friends from all over the world to visit our company and cooperate.

FAQ:

Q1. Are you factory, can I get factory low price?

Yes, we are a cable factory in Henan province, China. We will provide the best quality at a reasonable ex-work price.

Q2. How can I get a sample to check your quality?

After price confirmation, you can require samples to check our quality. The sample is free, but the freight charge should be paid.

Q3. Can I put my logo/company brand on the cable?

Yes, OEM ODM is available. Your logo can be marked on the cable as required.

Q4. What about the lead time for mass production?

Honestly, it depends on the order quantity and the season you place the order.

Q5. Certificate of your cable wire?

ISO9001, ISO14001, CE, and RoHS. Its products comply with international common standards such as IEC, BS, VDE, and GB

Send your message to this supplier
Send Now

Durable Overhead Aluminum Bare Conductor Cable Soild Power Electrical Wire AAC AAAC ACSR Stranded Aluminum Wire

Ask Latest Price
Watch Video
Supply Ability :
100 tons per day
Name :
Aluminium Conductor Cable
Model Number :
Quadruplex Triplex Duplex Service Drop
MOQ :
2000M
Delivery Time :
25days
Sample :
Free samples
Contact Supplier
video
Durable Overhead Aluminum Bare Conductor Cable Soild Power Electrical Wire AAC AAAC ACSR Stranded Aluminum Wire
Durable Overhead Aluminum Bare Conductor Cable Soild Power Electrical Wire AAC AAAC ACSR Stranded Aluminum Wire
Durable Overhead Aluminum Bare Conductor Cable Soild Power Electrical Wire AAC AAAC ACSR Stranded Aluminum Wire

Luoyang Sanwu Cable Co., Ltd.,

Verified Supplier
7 Years
henan, luoyang
Since 2016
Business Type :
Manufacturer, Exporter
Total Annual :
10000000-30000000
Employee Number :
50~200
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement