AllChekⅡ Blood Glucose Meter, Blood Glucose Sensor Device,Blood Glucose Test Strips
| Product Name: | AllChekⅡ Blood Glucose Meter, Blood Glucose Sensor Device,Blood Glucose Test Strips |
| Color: | Black |
| Format: | Meter |
| Certificate: | CE |
| Pack: | 1 Unit |
| Battery Life: | 1500 Tests |
| Results Calibration: | Plasma Equivalent |
| Operating Temperature: | 5°C-45°C |
| Brand: | AllChek |
| Principle: | Biochemical Assay |
| Specimen: | Whole Blood |
| Reading Time: | 5 Seconds |
| Shelf Life: | 5 Years |
| Battery Type: | CR 2450 3.0V Coin Cell Battery |
| Operating Humidity: | 20%-90% |
Thank you for choosing the AllChekⅡTM Blood Glucose Meter, the meter will give you accurate blood glucose results from capillary blood samples in just a few simple steps.
Please read this Package Insert and User Manual of the AllChekⅡTM Blood Glucose Meter carefully before take a blood glucose test.
Intended Use
Blood Glucose meter is designed for glucose measure quantitatively with fresh capillary whole blood. The system is intended for professional and self-testing in vitro diagnostic use as an aid to monitor the effectiveness of diabetes control. It is not used for the diagnosis of the diabetes or test of newborns.
To ensure accurate results from your Blood Glucose Meter,please follow below guidelines:
• For professional and self-testing in vitro diagnostic use.
• Read this User Manual carefully before use.
• The Blood Glucose Meter should only be used with Test Strips manufactured by AllTest.
• Do not change your medication or treatment plan without the permission of doctor.
• Keep out of reach of children and animals.
• Please use the meter in the way recommended by manufacturer, otherwise the meter may be damaged.
| Feature | Specification |
| Measurement Range | 1.1-33.3 mmol/L(20-600 mg/dL) |
| Result Calibration | Plasma-equivalent |
| Sample | Fresh whole blood (Capillary) |
| Minimum Sample Size | 1 pL |
| Test Time | 5 Seconds |
| On/Off Source | One CR 2450 3.0 V coin cell battery |
| Battery Life | Minimum of 1,500 measurements (without considering test reminder alarm) |
| Glucose Units of Measure | The Meter is pre-set to either millimoles per liter (mmol/L) or milligrams per deciliter(mg/dL) depending on the standard of your country |
| Memory | Up to 500 records with time and date |
| Automatic shutoff | 1 minute after last action |
| Meter Size | 83mmx57mmx22mm |
| Display Size | 40mmx36mm |
| Weight | 40g (with battery installed) |
| Operating Temperature | 5-45 oC |
| Operating Relative Humidity | 20-90% |
| Hematocrit Range | 25-60% |

1. Year/Month
2. Date
3. Minute
4. AM/PM
5. Blood sampling tips
6. Measurement Unit
7. Average flag
8. Memory Mode
9. Temperature tips
10. Low battery tips
11. Coding meter tips
12. Test result display
13. Alarm ON/OFF
14. Hour
Blood Glucose Range Information
It is very important for diabetics to track the blood glucose level with blood glucose monitoring. The system test results will help
doctor monitor the effectiveness of treatment for a better control of diabetes. Blood glucose varies throughout the course of a day. Normal blood glucose target ranges (from ADA Clinical Practice Recommendations, 2011)
| Time | Range (mg/dL) | Range (mmol/L) |
| Fasting and Before Meals | 70-100 | 3.9-5.6 |
| 2 hours after meal | <140 | <7.8 |
Summary
Blood Glucose Monitoring System is designed for glucose measure quantitatively with whole blood.The system is intended for professional in vitro diagnostic use as an aid to monitor the effectiveness of diabetes control.