AEW 100 is a multifunction power meter. There are functions like RS485 communication and Lora communication on 470MHz. With build-in MODBUS-RTU protocol, AEW100 can match most of the system integrate requirement. AEW100 has the advantage of higher accuracy, more compact and easy installing.
Technical Features
ADW2xx series subject Technical parameter
| Auxiliary power | AC/DC 85~265V;consumption≤10VA; | |
| Input | Frequency | 45~65Hz; |
| Voltage | AC 3×220V/380V; Overload: 1.2 times of rated value (continuous); 2 times of rated value / 1s; Power consumption:≤ 0.5VA; | |
| Current | AC 5A,100A,400A,600A;(External opening transformer); Overload: 1.2 times of rated value (continuous); 10 times of rated value / 1s; Power consumption:≤ 0.5VA; | |
| measurement accuracy | Frequency 0.05Hz, voltage and current 0.5 level, active electric energy level 1, reactive electric energy level 2; 2-31 times harmonic accuracy: ± 1%; | |
Features | Pulse output | Output mode: optocoupler pulse with open collector; |
| Communication | RS485,Modbus-RTU;Baud rate 1200~38400; | |
| Switching Input | Dry contact input,Built in power supply; | |
| Switching Output | Output mode:Relay normally open contact output; contact rating:AC 250V/3A DC 30V/3A; | |
ADW2xx series Module technical parameters
| Switching Module | Power | RJ45 interface,DC 12V,Power consumption≤1W; |
| Communication | RJ45 interface,Modbus-RTU;(Communication with the main Part) ; | |
| Switching input | Dry contact input,Built in power supply; | |
| Switching output | Output mode:Relay normally open contact output; contact rating:AC 250V/3A DC 30V/3A; | |
| Temperature and leakage module | Power | RJ45 interface,DC 12V,Power consumption≤1W; |
| Communication | RJ45 interface,Modbus-RTU;(Communication with the main Part) ; | |
| Temperature measurement | -20~100℃ | |
| Leakage measurement | 10~3000mA; | |
| Measurement accuracy | temperature ±2℃,Leakage1.0%; |
Quotation