Fire Resistant Aluminum Composite Panel For Building Material / Decoration
Fire Resistant Aluminum Composite Panels is one kind of the new decorative / building materials. made of by a fire resistant core with two layers of aluminum sheets. It is widely used in office buildings, shopping centers, industrial buildings, airports, hotels, bus stations, hospitals, schools, supermarkets, and residential buildings.
| Core Material | Normal PE | B1 | FR/HFR | A2 | 
| FR Ingredients | 100% | <50% | <30% | <10% | 
| Heat Value | >45 MJ/kg | <22 MJ/kg | <15 MJ/kg | <3 MJ/kg | 
| Oxygen Index | 16-18 | 28-30 | 32-34 | ≥80 | 
| FR Grade | CHN GB8624:B2 | CHN GB8624:B1 | CHN GB8624:B1-s1,d0,t0 EU EN13501:b-s1,d0 USA ASTME-84/NEPA285/ASTME-119 RU GOST30244-94/30402-96/12.1.044-89 UKR BV2.7-19-95(GOST30244-94) UK BS476Part6&7 GER DIN4102Part1  |  			CHN GB8624:A2-s1,d0,t0 EU EN13501:A2-s1,d0 SG PSB(BS476Part6&7):0,1  |  		
Physical Properties:
| No. | Item | Unit | Testing Method | Test Result | 
| 1 | Density | G/cm3 | GB/T 1033 | 1.60 | 
| 2 | Vicat Softening Point | ℃ | GB/T1633 | 86.2 | 
| 3 | Melting Point | ℃ | G/T 1033 | 96 | 
| 4 | Melt Index | Dg/min | GB/T3682185℃/2.18kg | 1.2~1.5 | 
|  			 No  |  			 			 
 Test item  |  			 			 
 Standard  |  			 			 
 Standard index  |  			 			 
 Text value  |  			 			 
 Result  |  		|
| 1 |  			 
 FIGRA ,W/S  |  			GB/T 20284-2006 |  			 
 
 
 B  |  			≤120 | 10 |  			 
 
 eligible  |  		
| 2 |  			 
 THR600s ,MJ  |  			GB/T 20284-2006 | ≤7.5 | 1.9 | ||
| 3 |  			 
 LFS ,m  |  			GB/T 20284-2006 |  			 
 <Sample side  |  			 			 
 Pass  |  		||
| 4 |  			 
 Fs ,mm  |  			GB/T 20284-2006 | ≤150 | 0 | ||
| 5 |  			 
 SMOGRA ,m2/s2  |  			GB/T 20284-2006 |  			 
 S1  |  			≤30 | 1 |  			 
 eligible  |  		
| 6 |  			 TSP600S ,m2  |  			GB/T 20284-2006 | ≤50 | 33 | ||
| 7 |  			 Drops after burning  |  			GB/T 20284-2006 |  			 
 d0  |  			 			 
 600s no drops after burning  |  			 			 
 Pass  |  			 			 
 
 eligible  |  		
| 8 |  			 If filter paper catch fire  |  			GB/T 8626-2007 |  			 
 Filter paper not catch fire  |  			 			 
 Pass  |  		||
| 9 |  			 Noxious fumes  |  			GB/T 20284-2006 | t1 | ZA3 | ZA3 |  			 
 eligible  |  		