Specifications
Brand Name :
MTL
Model Number :
MTL5511
Certification :
HART
Place of Origin :
UK/China
MOQ :
1
Price :
Negotiate
Payment Terms :
T/T
Supply Ability :
1000pcs per week
Delivery Time :
stock
Packaging Details :
carton
Voltage applied to sensor :
7 to 9V dc from 1kΩ ±10%
Response time :
10ms maximum
Contact rating (Zone 2) :
35V, 2A, 100VA
Maximum current consumption :
25mA at 24V
Power dissipation within unit :
0.6W at 24V
Dimensions (LxWxH) :
1.58 cm x 10.98 cm x 12.36 cm
Description

MTL5511 MTL Instruments Switch Proximity Detector Interface 10ms Maximum

The MTL5511 enables a safe-area load to be controlled by a switch or proximity detector located in a hazardous-area. When selected, open or short circuit conditions in the field wiring are detected by the line-fault-detect (LFD) facility and also indicated on the top of the module. Phase reversal for the channel is selected by a switch on the side of the module and output is provided by changeover relay contacts

  • Number of channels

    One

  • Location of switches

    Zone 0, IIC, T6 hazardous area

    Div. 1, Group A hazardous location

  • Location of proximity detector

    Zone 0, IIC, T4–6 hazardous area if suitably certified

    Div. 1, Group A hazardous location

  • Hazardous-area inputs

    Inputs conforming to BS EN60947–5–6:2001 standards for

  • proximity detectors (NAMUR)

    Voltage applied to sensor

    7 to 9V dc from 1kΩ ±10%

  • Input/output characteristics

    Normal phase

    Outputs closed if input > 2.1mA (< 2kΩ in input circuit)

    Outputs open if input < 1.2mA (> 10kΩ in input circuit)

    Hysteresis: 200μA (650Ω) nominal

  • Line fault detection (LFD) (when selected)

    User-selectable via switches on the side of the unit. A line fault is

    indicated by an LED. The channel output relay is de-energised if

    an input line fault is detected.

    Open-circuit alarm on if Iin < 50μA

    Open-circuit alarm off if Iin > 250μA

    Short-circuit alarm on if Rin < 100Ω

    Short-circuit alarm off if Rin > 360Ω

    Note: Resistors must be fitted when using the LFD facility with a contact

    input

    500Ω to 1kΩ in series with switch

    20kΩ to 25kΩ in parallel with switch

    Safe-area output

    Single pole relay with changeover contacts

    Note: reactive loads must be adequately suppressed

  • Relay characteristics

    Response time: 10ms maximum

    Contact rating: 250V ac, 2A, cosØ >0.7

    40V dc, 2A, resistive load

100VA MTL5511 MTL Instruments Switch 10ms Detector Proximity Sensor Interface

HCU16 MTL5521 MTL4575
HCU3700 MTL5522 MTL4646Y
HM64RIB20-1.0 MTL5531 MTL4850
HM64RIB20-1.5 MTL5532 MTL4851
HMM64 MTL5541 MTL4852
HMRIB16-1.0 MTL5541S MTL5018
HMS64 MTL5544 MTL5032
HTP-SC32 MTL5544D MTL5042
MTL4044D MTL5546 MTL5044
MTL4511 MTL5546Y MTL5049
MTL4516 MTL5561 MTL5511
MTL4516C MTL5573 MTL5514D
MTL4521 MTL5575 MTL5516
MTL4541 MTL5582B MTL5516C
MTL4541 MTL7728+ MTL7787P+
MTL4544 MTL7756AC MTLCPS16
MTL4544D MTL7760AC NJ5-18GK-N
MTL4546Y MTL7761PAC SD150X
MTL4549Y MTL7765AC SD32
MTL4573 MTL7787+ SD32X
TP48-4-N-NDI TP48-3-N-NDI SDRTD
TP48-N-NDI TP48-4-I-NDI SLP32D

Send your message to this supplier
Send Now

100VA MTL5511 MTL Instruments Switch 10ms Detector Proximity Sensor Interface

Ask Latest Price
Brand Name :
MTL
Model Number :
MTL5511
Certification :
HART
Place of Origin :
UK/China
MOQ :
1
Price :
Negotiate
Contact Supplier
100VA MTL5511 MTL Instruments Switch 10ms Detector Proximity Sensor Interface
100VA MTL5511 MTL Instruments Switch 10ms Detector Proximity Sensor Interface
100VA MTL5511 MTL Instruments Switch 10ms Detector Proximity Sensor Interface
100VA MTL5511 MTL Instruments Switch 10ms Detector Proximity Sensor Interface

Achievers Automation Limited

Verified Supplier
1 Years
hong kong
Since 2012
Business Type :
Distributor/Wholesaler, Agent, Trading Company
Total Annual :
3000000-5000000
Employee Number :
100~115
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement