Specifications
Brand Name :
Phoenix Contact
Model Number :
QUINT4-PS/3AC/24DC/40
Place of Origin :
Thailand
MOQ :
1
Price :
Negotiable
Payment Terms :
T/T,Western Union
Supply Ability :
500pcs/month
Delivery Time :
3 working days
Packaging Details :
original package
Condition :
original brand new
Warranty :
one year
Shipping way :
DHL FedEx express
Application :
Automation Industries, oil, gas, chemical industries
Certificate :
CE ISO TUV
Description

Primary-switched QUINT POWER power supply with free choice of output characteristic curve, SFB (selective fuse breaking) technology, and NFC interface, input: 3-phase, output: 24 V DC/40 A

The fourth generation of the high-performance QUINT POWER power supplies ensures superior system availability by means of new functions. Signaling thresholds and characteristic curves can be individually adjusted via the NFC interface.
The unique SFB technology and preventive function monitoring of the QUINT POWER power supply increase the availability of your application.

Control input (configurable) Rem Output power ON/OFF (SLEEP MODE)
Default Output power ON (>40 kΩ/24 V DC/open bridge between Rem and SGnd)
AC operation
Network type Star network
Nominal input voltage range 3x 400 V AC ... 500 V AC
2x 400 V AC ... 500 V AC
Input voltage range 3x 400 V AC ... 500 V AC -20 % ... +10 %
2x 400 V AC ... 500 V AC -10 % ... +10 %
Typical national grid voltage 400 V AC
480 V AC
Voltage type of supply voltage AC
Inrush current typ. 1.5 A (at 25 °C)
Inrush current integral (I2t) < 0.06 A2s
Inrush current limitation 1.5 A (after 1 ms)
AC frequency range 50 Hz ... 60 Hz -10 % ... +10 %
Frequency range (fN) 50 Hz ... 60 Hz -10 % ... +10 %
Mains buffering time typ. 28 ms (3x 400 V AC)
typ. 28 ms (3x 480 V AC)
Current consumption 3x 1.8 A (400 V AC)
3x 1.5 A (480 V AC)
2x 3 A (400 V AC)
2x 2.5 A (480 V AC)
3x 1.5 A (500 V AC)
2x 2.4 A (500 V AC)
Nominal power consumption 1217 VA
Protective circuit Transient surge protection; Varistor, gas-filled surge arrester
Power factor (cos phi) 0.95
Switch-on time < 1 s
Typical response time 300 ms (from SLEEP MODE)
Recommended breaker for input protection 3x 4 A ... 20 A (Characteristic B, C, D, K or comparable)
Recommended fuse for input protection ≥ 300 V AC
Discharge current to PE < 3.5 mA
1 mA (550 V AC, 60 Hz)
DC operation
Nominal input voltage range ± 260 V DC ... 300 V DC
Input voltage range ± 260 V DC ... 300 V DC -13 % ... +30 %
520 V DC ... 600 V DC -13 % ... +30 % (mid-point earthed)
Voltage type of supply voltage DC
Current consumption 2.2 A (±260 V DC)
1.9 A (±300 V DC)
Nominal power consumption 1217 VA
Recommended breaker for input protection 1x 6 A (10 x 38 mm, 30 kA L/R = 2 ms)
Recommended fuse for input protection ≥ 1000 V DC


Send your message to this supplier
Send Now

2904623 Phoenix Contact Power Supply QUINT4-PS/3AC/24DC/40 24 VDC 40A output

Ask Latest Price
Brand Name :
Phoenix Contact
Model Number :
QUINT4-PS/3AC/24DC/40
Place of Origin :
Thailand
MOQ :
1
Price :
Negotiable
Payment Terms :
T/T,Western Union
Contact Supplier
2904623 Phoenix Contact Power Supply QUINT4-PS/3AC/24DC/40 24 VDC 40A output
2904623 Phoenix Contact Power Supply QUINT4-PS/3AC/24DC/40 24 VDC 40A output

Shenzhen Hengyo Power Technology Co., Limited

Verified Supplier
1 Years
shenzhen
Since 2013
Business Type :
Distributor/Wholesaler, Exporter, Seller, Manufacturer, Trading Company
Total Annual :
2000000-5000000
Employee Number :
20~50
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement