8BVP0880HC00.004-1 B&R PLC ACOPOSmulti Power Supply Module
  
   
   
  MATERIAL NUMBER:
  8BVP0880HC00.004-1
  DESCRIPTION:
    	- Extensive input voltage range
  	- Capable of regeneration
  	- Integrated connection for temperature sensors
  	- 2 slots for ACOPOSmulti plug-in modules
  
  ACOPOSmulti power supply module, 88 A, AS, cold plate or pass-through mounting
   
   General information
    	 		 			| B&R ID code |  			0xA6A1 |  		
 		 			| Cooling and mounting type |  			Cold plate or pass-through mounting |  		
 		 			| Slots for plug-in modules |  			2 |  		
 		 			| Certifications |  			  |  		
 		 			| CE |  			Yes |  		
 		 			| UL |  			cULus E225616  			Power conversion equipment |  		
 		 			| EAC |  			Yes |  		
 		 			| KC |  			Yes |  		
 	 
       Mains connection
    	 		 			| Network configurations |  			TT, TN-S, TN-C-S |  		
 		 			| Mains input voltage |  			3x 220 to 3x 480 VAC ±10% |  		
 		 			| Frequency |  			50 / 60 Hz ±4% |  		
 		 			| Installed load |  			Max. 62 kW |  		
 		 			| Inrush current at 400 VAC |  			Max. 133 A |  		
 		 			| Switch-on interval |  			>300 s |  		
 		 			| Max. DC bus capacitance depending on mains voltage |  			  |  		
 		 			| 230 VAC |  			34.8 mF |  		
 		 			| 400 VAC |  			11.5 mF |  		
 		 			| 480 VAC |  			8 mF |  		
 		 			| Nominal switching frequency |  			5 kHz |  		
 		 			| Possible switching frequencies |  			5 / 10 kHz |  		
 		 			| Integrated line filter per EN 61800-3, category C3 |  			No |  		
 		 			| Integrated regeneration choke |  			No |  		
 		 			| Regenerative |  			Yes |  		
 		 			| Power factor correction (PFC) |  			Yes |  		
 		 			| Variant |  			  |  		
 		 			| L1, L2, L3, PE |  			M8 threaded bolts |  		
 		 			| Shield connection |  			Yes |  		
 		 			| Connection cross section range |  			  |  		
 		 			| Flexible and fine-stranded wires |  			--- |  		
 		 			| Terminal cable cross section dimension of shield connection |  			32 to 50 mm |  		
 	 
       DC bus connection
    	 		 			| Voltage |  			  |  		
 		 			| Nominal |  			750 VDC |  		
 		 			| Continuous power (supply and regeneration) |  			60 kW |  		
 		 			| Reduction of continuous power depending on mains input voltage |  			  |  		
 		 			| Mains input voltage <3x 400 VAC |  			150 W/V * (400 V - Mains input voltage) |  		
 		 			| Reduction of continuous power depending on DC bus voltage (UDC) |  			  |  		
 		 			| UDC <750 VDC |  			0.08 kW/V |  		
 		 			| Reduction of continuous power depending on switching frequency and mounting type |  			  |  		
 		 			| Switching frequency 5 kHz |  			  |  		
 		 			| Cold plate mounting |  			1.3 kW/K (starting at 58°C) |  		
 		 			| Pass-through mounting |  			In preparation |  		
 		 			| Switching frequency 10 kHz |  			  |  		
 		 			| Cold plate mounting |  			0.95 kW/K (starting at 27°C) |  		
 		 			| Pass-through mounting |  			In preparation |  		
 		 			| Reduction of continuous power depending on installation elevation |  			  |  		
 		 			| Starting at 500 m above sea level |  			6 kW per 1000 m |  		
 		 			| Peak power (supply and regeneration) |  			120 kW |  		
 		 			| Power dissipation depending on switching frequency |  			  |  		
 		 			| Switching frequency 5 kHz |  			[0.065*P²+11.4*P+90] W |  		
 		 			| Switching frequency 10 kHz |  			[0.22*P²+16.1*P+185] W |  		
 		 			| DC bus capacitance |  			1650 µF |  		
 		 			| Protective measures |  			  |  		
 		 			| Overload protection |  			Yes |  		
 		 			| Short-circuit and ground fault protection |  			No |  		
 		 			| Variant |  			ACOPOSmulti backplane |  		
 	 
       24 VDC power supply
    	 		 			| Input voltage |  			25 VDC ±1.6% |  		
 		 			| Input capacitance |  			4.7 µF |  		
 		 			| Max. power consumption |  			27 W + PSLOT1 + PSLOT2 + P24 V Out + PFan8BVF... |  		
 		 			| Variant |  			ACOPOSmulti backplane |  		
 	 
       24 VDC Out
    	 		 			| Quantity |  			2 |  		
 		 			| Output voltage |  			  |  		
 		 			| DC bus voltage (UDC): 260 to 315 VDC |  			25 VDC * (UDC / 315) |  		
 		 			| DC bus voltage (UDC): 315 to 800 VDC |  			24 VDC ±6% |  		
 		 			| Fuse protection |  			250 mA (slow-blow) electronic, automatic reset |  		
 	 
       Filter fan connection
    	 		 			| Output voltage |  			24 V +5.8% / -0.1% |  		
 		 			| Continuous current |  			4.2 A |  		
 		 			| Max. overcurrent limiting |  			10 A |  		
 		 			| Protective measures |  			  |  		
 		 			| Overload protection |  			No |  		
 		 			| Short-circuit proof |  			Yes |  		
 		 			| Open-circuit monitoring |  			No |  		
 		 			| Undervoltage monitoring |  			No |  		
 	 
       Trigger inputs
    	 		 			| Quantity |  			2 |  		
 		 			| Circuit |  			Sink |  		
 		 			| Electrical isolation |  			  |  		
 		 			| Input - Power supply module |  			Yes |  		
 		 			| Input - Input |  			Yes |  		
 		 			| Input voltage |  			  |  		
 		 			| Nominal |  			24 VDC |  		
 		 			| Maximum |  			30 VDC |  		
 		 			| Switching threshold |  			  |  		
 		 			| Low |  			<5 V |  		
 		 			| High |  			>15 V |  		
 		 			| Input current at nominal voltage |  			Approx. 10 mA |  		
 		 			| Switching delay |  			  |  		
 		 			| Rising edge |  			52 μs ±0.5 μs (digitally filtered) |  		
 		 			| Falling edge |  			53 μs ±0.5 μs (digitally filtered) |  		
 		 			| Modulation compared to ground potential |  			Max. ±38 V |  		
 	 
       Electrical properties
    	 		 			| Discharge capacitance |  			0.9 µF |  		
 	 
       Operating conditions
    	 		 			| Permissible mounting orientations |  			  |  		
 		 			| Hanging vertically |  			Yes |  		
 		 			| Horizontal, face up |  			Yes |  		
 		 			| Standing horizontally |  			No |  		
 		 			| Installation elevation above sea level |  			  |  		
 		 			| Nominal |  			0 to 500 m |  		
 		 			| Maximum |  			4000 m |  		
 		 			| Pollution degree per EN 61800-5-1 |  			2 (non-conductive pollution) |  		
 		 			| Overvoltage category per EN 61800-5-1 |  			III |  		
 		 			| Degree of protection per EN 60529 |  			IP20 |  		
 	 
       Ambient conditions
    	 		 			| Temperature |  			  |  		
 		 			| Operation |  			  |  		
 		 			| Nominal |  			5 to 40°C |  		
 		 			| Maximum |  			55°C |  		
 		 			| Storage |  			-25 to 55°C |  		
 		 			| Transport |  			-25 to 70°C |  		
 		 			| Relative humidity |  			  |  		
 		 			| Operation |  			5 to 85% |  		
 		 			| Storage |  			5 to 95% |  		
 		 			| Transport |  			Max. 95% at 40°C |  		
 	 
       Mechanical properties
    	 		 			| Dimensions |  			  |  		
 		 			| Width |  			213.5 mm |  		
 		 			| Height |  			317 mm |  		
 		 			| Depth |  			  |  		
 		 			| Cold plate |  			212 mm |  		
 		 			| Pass-through mounting |  			209 mm |  		
 		 			| Weight |  			Approx. 7.9 kg |  		
 		 			| Module width |  			4 |