Product characteristics:
♦ The voltage can be set at a maximum of 10-100V, charging current 0-20A, discharge current 0-40A
♦ At the same time, aging positive plate can protect negative plate discharge protection
♦ By charging and discharge cycle of the battery, you can detect whether the charging protection and discharge protection of the battery are normal
♦ Charge and discharge cycle on the battery and record the charging capacity and discharge capacity
♦ The equipment has anti-reverse protection function. The device number is displayed through LED lamp, and the corresponding number can be inquired at any time
♦ The instrument provides P + and P-interfaces, and CH + and CH-, can test special finished batteries
♦ The equipment has a safe discharge current protection function
♦ PC computers can be connected through the serial port to reduce the complexity of instrument use
♦ Network connection mode can be adopted, and the PC computer terminal can control within 254 instruments by only providing one network port
♦ The software system adopts a classic and mature C/S mode
♦ Communication modes have serial port and network mode equipment with voltage upper and lower limit setting protection
♦ The serial port can realize the accurate communication of several instruments for short distances
♦ The network can achieve long-distance multiple instrument preparation communication
♦ The device can view the charge and discharge aging curve and export the curve diagram
♦ In network mode, automatic online, no manual online
| Input Power | AC 380V 2kw 50/60Hz | |
| Voltage | Measuring range | 10~100V |
| Precision | ±(0.2% of reading + 0.2% of range) | |
| Electric Current | Charging range | 2~20A |
| Charging accuracy | ±(0.2% of reading + 0.2% of range) | |
| Discharge range | 2~40A | |
| Precision | ±(0.2% of reading + 0.2% of range) | |
| Charging | Constant voltage cut-off current | (minimum)10mA |
| Capacity | Precision | ±1‰ |
| Power | Discharge power | 4000W |
| Time | Inspection time | <2S(Receive real-time & LT; 2s) |
| Timing range | 0 ~ 999 hours / Step | |
| Data recording interval | ≥5S | |
| Median version | 1.1 series | |
| Charging | Charging mode | Constant current and constant voltage charging |
| Cut-off condition | Voltage, current, relative time, overcharge protection | |
| Discharge | Discharge mode | Constant current discharge |
| Cut-off condition | Voltage, relative time, over-discharge protection | |
| Circulates | Cyclic range | 1~999 |
| Single cycle number of steps | 100 | |
| Voltage and current detection sampling | Four wire connection | |
| Noise | <50dB | |
| Database | Using My SQL database to manage test data | |
| Communication Mode of upper computer | Based on TCP / IP Protocol, serial port | |
| Data output mode | EXCEL,TXT,Chart | |
| Communication interface | Mesh opening | |
| Number of channels per cabinet | Single Channel | |
| Case size | W*D*H:800MM*520MM*1370MM | |
| Cabinet size | W*D*H:700MM*400MM*420MM | |